(exactly one of SW3-1 and SW3-2 should be on; the other should be off)
SW3-1	Select standard address range (17772520)
SW3-2   Select non-standard address range set by jumpers:
	E to D	772440
	F to D	776300
	G to D	777460

(enable as many units as you have transports with SW3-3 through 3-6)
SW3-3	Enable unit 0 (at base CSR and unit 0 VECTOR)
SW3-4	Enable unit 1 (at base CSR+4 and base VECTOR+4)
SW3-5	Enable unit 2 (at base CSR+10 and base VECTOR+10)
SW3-6	Enable unit 3 (at base CSR+14 and base VECTOR+14)

SW2-8	On: unit 0 VECTOR is 224
	Off: unit 0 VECTOR set by SW2-7 through SW2-1
SW2-7	base VECTOR bit 08
SW2-6	base VECTOR bit 07
SW2-5	base VECTOR bit 06
SW2-4	base VECTOR bit 05
SW2-3	base VECTOR bit 04
SW2-2	base VECTOR bit 03
SW2-1	base VECTOR bit 02
       (VECTOR bits 00-01 are always zero)

SW1-1	On=RUN; Off=RESET.  Normal position is RUN.
SW1-2	Special Formatted/Streaming Daisy Chain Option.  Normal positon is OFF.
SW1-3	On=16-word DMA bursts.  Off=4-Word DMA bursts.
SW1-4	On=Formatted transport operation; Off=Streaming tape operation.
SW2-9	On=select CDC GCR mode.
SW2-10  On=allow extended interblock gap in streaming mode;
        Off=allow only normal interblock gap.

SW3-7	Off=normal operation; On=include delay for VAX Diagnostics.
SW3-10	Off=normal write data strobe; On=inverted write data strobe.
SW3-8	On=allow software selection of density mode; Off=normal.