FTN4,L
      SUBROUTINE TSYTM(IUNIT,IEVNT,IEXTT,IMANT,INPUT,IFREQ),
     +09580-16455 REV.2001 790821 
C 
C-------------------------------------
C 
C  HP 5359A TIME SYNTHESIZER
C 
C  RELOCATABLE 09580-16455
C  SOURCE      09580-18455
C 
C  BOB RICHARDS  790821 
C 
C------------------------------------ 
C 
C  !=================================================!
C  !                                                 !
C  ! (C) COPYRIGHT HEWLETT-PACKARD COMPANY 1979      !
C  !                ALL RIGHTS RESERVED              !
C  !                                                 !
C  ! NO PART OF THIS PROGRAM MAY BE PHOTOCOPIED,     !
C  ! REPRODUCED OR TRANSLATED INTO ANOTHER PROGRAM   !
C  ! LANGUAGE WITHOUT THE PRIOR WRITTEN CONSENT OF   !
C  ! THE HEWLETT-PACKARD COMPANY.                    !
C  !                                                 !
C  !-------------------------------------------------!
C  !                                                 !
C  ! TEST SYSTEM SOURCE SOFTWARE IS THE PROPRIETARY  !
C  ! MATERIAL OF THE HEWLETT-PACKARD COMPANY.        !
C  !                                                 !
C  ! THIS SOURCE DATA SHALL BE USED SOLELY IN        !
C  ! CONJUNCTION WITH ELECTRONIC COMPUTER SYSTEMS    !
C  ! SUPPLIED TO THE USER BY HEWLETT-PACKARD.        !
C  !                                                 !
C  ! THIS PROPRIETARY DATA SHALL NOT BE COPIED OR    !
C  ! OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN  !
C  ! CONSENT OF HEWLETT-PACKARD, EXCEPT THAT ONE     !
C  ! COPY MAY BE MADE AND RETAINED BY THE USER FOR   !
C  ! ARCHIVE PURPOSES.                               !
C  !                                                 !
C  ! THE USER SHALL NOT DISCLOSE THIS DATA TO ANY    !
C  ! THIRD PARTIES WITHOUT THE PRIOR WRITTEN CONSENT !
C  ! OF HEWLETT-PACKARD. IN ADDITION, THE USER SHALL !
C  ! USE AT LEAST THE SAME CARE AND SAFEGUARDS TO    !
C  ! PROTECT THIS DATA FROM UNAUTHORIZED USE OR      !
C  ! DISCLOSURE AS THE USER USES TO PROTECT ITS OWN  !
C  ! PROPRIETARY DATA.                               !
C  !                                                 !
C  !=================================================!
C 
C  GENERAL: 
C  -------- 
C 
C    THE FOLLOWING DEVICE SUBROUTINES ARE USED
C   TO PROGRAM THE HP-5359A TIME SYNTHESIZER. 
C 
C  HARDWARE REQUIRED: 
C  ------------------ 
C    A. HP 5359A
C    B. HP59310  BUS INTERFACE KIT. 
C 
C         JUMPER POSITION:
C          SW1-1 - 1
C          SW1-2 TO SW1-8 - 0 
C          SW2-1 - 0
C          SW2-2 - 0
C          SW2-3 - 0
C          SW2-4 - 0
C          SW2-5 - 1
C          SW2-6 - REN
C          SW2-7 - ICF
C          SW2-8 - CNX
C 
C    C. HP 21XX SERIES COMPUTER 
C 
C  BRANCH AND MNEMONIC TABLE ENTRIES: 
C  ---------------------------------- 
C 
C    TSYTM(I,I,I,I,I,I)     OV=XX,   ENT=TSYTM,   FIL=%TSYTM
C 
C  CONFIGURATION TABLE ENTRIES: 
C  ---------------------------- 
C 
C    R 51,1,42
C    U1 
C    *
C        0    * 42 "0" ENTRIES
C        0
C        0
C        0
C        .
C        .
C 
C        0
C 
C 
C 
C------------------------------------ 
C 
C  TSYTM(IUNIT,IEVNT,IEXTT,IMANT,INPUT,IFREQ) 
C 
C    WHERE: 
C 
C       IUNIT = UNIT #
C 
C       IEVNT = EVENTS SLOPE
C             -1 = - SLOPE
C              0 = NO COMMAND 
C             +1 = + SLOPE
C 
C       IEXTT = EXTERNAL TRIGGER SLOPE
C               -1 = - SLOPE
C                0 = NO COMMAND 
C               +1 = + SLOPE
C 
C       IMANT = TRIGGER MANUAL FUNCTION 
C              -1 = MANUAL FUNCTION 
C               0 = NO COMMAND
C              +1 = AUTO TRIGGER
C 
C       INPUT = TRIGGER INPUT 
C              -1 = DISABLE 
C               0 = NO COMMAND
C               1 = ENABLE
C 
C       IFREQ = TRIGGER FREQUENCY 
C              -1 = TRIGGERED FREQUENCY ON
C               0 = NO COMMAND
C               1 = NORMAL FREQUENCY - NO TRIGGER NEEDED
C 
C 
C 
C 
C------------------------------------ 
      DIMENSION IERMS(5)
      DATA IDTN / 51 /
      DATA IERMS / 10,5,2HTS,2HYT,2HM  /
C 
      IERMS=10
C 
C  FIND STATION AND LU #'S
C   ISTN = STATION #
C   LU1 = HP-5359A LU 
C   LUIB = HP-IB LU 
C 
      ISTN=ISN(DUMMY) 
      LU1=LUDV(ISTN,IDTN,IUNIT) 
      LUIB=IBLU0(LU1) 
      IF(LU1 .LE. 0 .OR. LUIB .LE. 0)GOTO 800 
C 
C  CALL X SUB 
C 
      CALL XSYTM(LU1,LUIB,IERMS,IUNIT,IEVNT,IEXTT,IMANT,INPUT,IFREQ)
      IF(IERMS)800,20,800 
C 
C  EXIT 
C 
20    RETURN
C 
C  ERROR EXIT 
C 
800   CALL ERROR(IERMS,IERMS(2))
      RETURN
      END 
C 
C---------------------------------------------
C 
      SUBROUTINE XSYTM(LU1,LUIB,IERMS,IUNIT,IET,IEXTT,IMANT,INPUT,
     +IFREQ),09580-16455 REV.2001 790821
      DIMENSION IERMS(5),IOBUF(5),IFS(6)
C 
C---------------------------------------------
C 
C 
C  THE PARAMETERS IN THE CALLING SEQUENCE HAVE THE FOLLOWING
C  MEANINGS.
C 
C     LUIB = LU # OF HP-IB BUS. 
C     LU1  = LU # OF HP-5359A 
C 
C    IERMS IS A FIVE WORD ARRAY WITH IERR(1) CONTAINING 
C      THE ERROR CODE.
C 
C        0 = NO ERROR 
C        1 = PARAMETER ERROR
C 
C    ERROR MESSAGES THAT PERTAIN TO THE HP-IB.
C 
C        9 = I/O CALL REJECTED
C       10 = LUIB OR LU1 = 0
C       12 = I/O DEVICE TIME OUT
C       13 = IFC DETECTED DURING I/O REQUEST
C       14 = SRQ ABORTED
C       15 = NON-EXISTENT ALARM PROGRAM 
C       16 = ILLEGAL CONTROL REQUEST
C       17 = EQT EXTENSION AREA FULL
C 
C    IERMS(2) = ERROR MNEMONIC CHARACTER COUNT
C    IERMS(3) TO IERMS(5) = ERROR MNEMONIC
C 
C 
C---------------------------------------------
C 
C 
C 
C 
C  CHECK PARAMETERS 
C 
      IERMS=1 
      IF (IET .LT. -1 .OR. IET .GT. 1) GO TO 8000 
      IF(IEXTT .LT. -1 .OR. IEXTT .GT. 1) GO TO 8000
      IF(IMANT .LT. -1 .OR. IMANT .GT. 1) GO TO 8000
      IF(INPUT .LT. -1 .OR. INPUT .GT. 1) GO TO 8000
      IF(IFREQ .LT. -1 .OR. IFREQ .GT. 1) GO TO 8000
C 
C  SET UP OUTPUT BUFFER 
C 
C 
      DO 200 I = 1,5
      IOBUF(I) = 20040B 
200   CONTINUE
C 
C 
      IF (IET .EQ. -1) IOBUF(1) = 2HEN
      IF (IET .EQ. 1) IOBUF(1) = 2HEP 
      IF (IEXTT .EQ. -1) IOBUF(2) = 2HTN
      IF (IEXTT .EQ. 1) IOBUF(2) = 2HTP 
      IF (IMANT .EQ. -1) IOBUF(3) = 2HTM
      IF (INPUT .EQ. -1) IOBUF(4) = 2HID
      IF (INPUT .EQ. 1) IOBUF(4) = 2HIE 
      IF (IFREQ .EQ. -1) IOBUF(5) = 2HTF
      IF (IFREQ .EQ. 1) IOBUF(5) = 2HNF 
      INUM = 5
C 
C 
C  REMOTE ENABLE
C 
2000  CALL EXEC(100003B,1600B+LUIB) 
      GOTO 9000 
70    CALL ABREG(IA,IB) 
      IF(IB .LT. 0) GOTO 8500 
C 
C  SEND OUTPUT BUFFER 
C 
      CALL REIO(100002B,LU1,IOBUF(1),INUM,IDUMY,0)
      GOTO 9000 
71    CALL ABREG(IA,IB) 
      IF(IB .LT. 0) GOTO 8500 
C 
C 
C  RETURN 
C 
      IERMS=0 
      RETURN
C 
C  ERROR EXIT 
C 
8500  IERMS=IAND(IA,377B)+11
      GOTO 8000 
9000  IERMS=9 
8000  IERMS(2)=5
      IERMS(3)=2HTS 
      IERMS(4)=2HYT 
      IERMS(5)=2HM
      RETURN
      END 
      END$
                                                                                    