                         PDP-1 COMPUTER
               ELECTRICAL ENGINEERING DEPARTMENT
             MASSACHUSETTS INSTITUTE OF TECHNOLOGY
                 CAMBRIDGE, MASSACHUSETTS 02139


















                            PDP-35-3

                       INSTRUCTION MANUAL

             PART 3 -- I/O AND MASS MEMORY DEVICES





















                        February 2, 1975












                >>13<<r                                

   Most I/O devices must be assigned before they are used.  This
avoids conflicts since only  the program which  has a given  I/O
unit assigned can use that unit.

   Many  I/O devices are operated with  the ivk (op code 740000)
instruction.  All such  devices used by  a program are  accessed
through a program-selectable number called a "C-list index". The
low 6 bits of  the ivk instruction are  the C-list index of  the
device to be operated. There are a few conventions regarding the
indices assigned to certain types  of devices. For example,  the
paper tape reader is typically operated as device number 10, and
the punch as device 11. They could be assigned as other numbers,
however.   All devices operated by ivk's (except the typewriter)
are assigned with "mta" instructions, usually mta 306. The low 6
bits  of the AC give  the required C-list index  and the rest of
the AC determines which I/O device is desired.  Thus, the reader
is  typically assigned with AC =  30010 and is operated with ivk
10.  Indices must be between 0  and 17 for most programs. It  is
possible  to  increase  the upper  limit  to 77  by  running the
program in "PRL" mode.


   Devices cannot be assigned unless the specified C-list  index
is free, i.e. no device of any kind already occupies that index.
Hence, if  the  reader  is  already  assigned  at  index  10,  a
subsequent attempt to assign it at index 10 would fail, not only
because index 10 is occupied, but because the reader is  "busy".
(The  fact  that the  present owner  of the  reader is  the same
program as the one  trying to assign it  again makes no  differ-
ence.)

   The  mta instruction that assigns such  a device will skip if
the assignment is  successful, i.e. the  requested C-list  index
was  free and the device was available (not assigned to the same
or another console.)

   All devices  operated by  the ivk  instruction are  dismissed
with  the mta 204 (770274) instruction  with the C-list index in
the low 6 bits of the AC.

   The console typewriter is the one exception to the rule  that
all  devices operated by ivk instructions  must be assigned by a
mta instruction. When a  user logs in,  the typewriter for  that
console is automatically assigned at index zero.


	The W Register

   Many  IO  devices  that  are  interpreted  by  the supervisor
require that more information be  suuplied than will fit in  the
AC  and IO. Therefore, there is another register, called the "W"
register, which exists inside the supervisor. A program can read
and  write  its  W  register  with  the  following instructions.

    mta 0     Copy A into W
    mta 1     Copy I into W
    mta 2     Copy W into A
    mta 3     Copy W into I






                >>13<<>>52<<                                
If an I/O device operation requires information in all three  of
A, I, and W, the program will typically load the data for W into
the AC, transmit it to  W with a mta, load  the data for the  AC
and IO, and then execute the ivk.





























































                >>13<<>>34<<                                
	Typewriters

   The instructions for operating the typewriters are

Instruction     Action

ivk 100       Type out 6-bit character in A(12-17).

ivk 200       Type in 6-bit character to A(12-17), clearing A(0-11).

ivk 300       Type out 6-bit character in I(12-17).

ivk 400       Type in 6-bit character to I(12-17), clearing I(0-11).

ivk 1300      Type out 7-bit character in A(11-17).

ivk 1400      Type in 7-bit character to A(11-17), clearing A(0-10).

ivk 1500      Type out 7-bit character in I(11-17).

ivk 1600      Type in 7-bit character to I(11-17), clearing I(0-10).

   On  typeout,  bits other  than  the ones  noted  are ignored.

   6-bit characters are the ones used by the actual typewriters.
Programs  operating  typewriters in  6-bit mode  must explicitly
handle upshift (74) and downshift (72) characters.

   In 7-bit mode, the timesharing supervisor handles case shifts
automatically.  The "100" bit  (bit 11) of a  character is on if
the character is in upper case.

   See the appendix to the assembler memo (PDP-45) for a list of
character codes.

   All type-out instructions wait  until the typewriter is ready
to accept  them,  i.e.  the  supervisor  handles  the  necessary
synchronization.  Type-in  instructions  wait  until  a  key  is
struck.

   There are  some other  typewriter  operations, used  only  in
multiple  sphere applications, which are  described in part 5 of
the instruction manual.






















                >>13<<e                                
	Paper Tape Reader

   The PDP-1 has  a photoelectric paper  tape reader capable  of
reading  320 or  640 lines per  second, as selected  by a toggle
switch on the left side of the reader rack (bay 11).  Eight-hole
tape  is normally  used, although five  and seven  hole tape may
also be read.

   The reader operates in  one of two  modes, alpha and  binary.
The  mode  is decided  at the  time the  reader is  assigned and
cannot be changed except by  dismissing and assigning it  again.

   The  reader is assigned with the instruction mta 306 (770376)
with AC = 300NN for alpha  mode and 301NN for binary mode.  This
instruction will skip if the assignment is successful. In either
mode  the  reader  is  operated  with  the  instruction  ivk  NN
(7400NN).  NN is often chosen as 10.

Alpha mode

   One line of tape is read and placed in the AC. Channel 1 (the
end channel on the edge of the tape closer to the feedholes)  is
read  into bit 17, channel 2 into bit 16, etc. for the number of
channels on the tape. A(0-9) is cleared. If the reader is out of
tape,  the ivk does not skip. Otherwise the  ivk will skip after
the data has been read.

Binary mode

   Three lines of tape  are read. Channel  8 must always  appear
punched>>40<<,  if  not,  the line  is  ignored. Channel  7  is always
ignored.  Channels six through one of the first line are  placed
in  A(0-5).  A(6-11) is filled from the second line of tape, and
A(12-17) from the third. If the  reader is out of tape, the  ivk
does  not skip. Otherwise  the ivk will skip  after the data has
been read.

   The system  will do  a  certain amount  of buffering  of  the
input. Thus, if a program reads one line of tape, the supervisor
will read many additional lines,  which it will transmit to  the
program  when  subsequent ivk's  are  executed. If  the  tape is
removed from the reader and replaced by another tape, the result
may  not  be what  is desired.  The  supervisor's buffer  can be
cleared by releasing the reader and re-assigning it.





















                >>13<<                                
	Paper Tape Punch

   The PDP-1 paper tape  punch punches standard eight-hole  tape
at a speed of 63 lines per second.

   The  punch is assigned with the instruction mta 306 with AC =
400NN, and operated  with the  instruction ivk NN.  NN is  often
chosen as 11.

   The  punch ivk  causes one line  of tape to  be punched. Tape
channels eight through one come from A(10-17) respectively.  The
rest  of  the AC  is ignored.  The  feedhole is  always punched.





















































                >>13<<	                                
	CRT Display

   The  display  is intended  to be  used as  an on-line  output
device  for the PDP-1.  It is useful for high speed presentation
of graphs, diagrams, drawings, and alphanumeric information. The
unit  uses solid-state circuits and  has magnetic deflection and
focus. The cathode ray tube has a P7 phospher, allowing either a
blue  or yellow filter  to be used  to select the  short or long
persistence for  photography purposes.  Some characteristics  of
the display are --

	1024 by 1024 addressable locations
	Plots 20,000 points per second
	Random point plotting
	Accuracy of point is 3 percent of raster size
	Raster size is 9.25 by 9.25 inches
	Origin may be at one of four points under control of
		each display instruction
	Brightness may be controlled to one of 8 levels under
		control of each display instruction


   To  the unaided eye, approximately  512 points are resolvable
on each axis. Five of the eight brightness levels are considered
visible.   A photomultiplier tube may see all brightness levels.

   Note that this device is  not operated with the ivk  instruc-
tion.   The display  does not  need to  be assigned.   It can be
operated from any console at any time.

   The dpy instruction (73cb07) causes one point to be displayed
on the scope. A(0-9) specifies the X coordinate and I(0-9) gives
the Y  coordinate.   A and  I  remain unchanged  after  the  dpy
instruction.   The three "b" bits  control the brightness -- the
order is  4,  5,  6, 7,  0,  1,  2,  3 where  4  is  visible  to
photomultiplier  tubes, 7 is barely visible,  0 is normal, and 3
is the brightest.  The "c"  bits control the centering. 0  makes
the  origin in the center of the scope.  1 puts it at the center
of the bottom edge.  2 makes the origin be half way up the  left
edge, while 3 puts it at the lower left corner.

   A  dpy (that is, with the  i-bit on) takes 40 microseconds to
complete. dpy-i (iot 7) does not wait for the scope to complete.
Since  it  is impossible  to activate  the  scope too  fast, one
normally executes iot 7 instructions. This allows the program to
continue while the scope is running.

   Subroutines  for  plotting  points  and  lines  exist  in the
relocatable subroutine library.
















                >>13<<7                                
	Light Pen

   The light pen is designed to be used with the CRT display.  A
program utilizing the light pen can give the user the ability to
make choices by  pointing at  the display.  For  example, a  CRT
editor  program could  let the user  point the light  pen at the
displayed text to specify  the character or  line to be  edited.

   About  39 microseconds after the last dpy (or dpy-i) instruc-
tion has  occurred, a  scope completion  pulse interrogates  the
light pen. If it is seeing light at that time, program flag 3 is
set.  By  clearing  flag  3, displaying  a  point,  waiting  the
requisite  40 microseconds and  then checking flag  3, a program
can determine whether the  light pen saw  light.  Note that  the
light  does not have  to come from the  scope face.  A threshold
control for the light pen  sensitivity is located on the  bottom
of the scope tube cabinet.

   If  a  program  uses  dpy  instructions  (that  is,  the  iot
instruction with the  i-bit on), flag  3 will be  set, if it  is
going  to be, when  the dpy completes.  If  a program uses dpy-i
instructions, there must be at least 40 microseconds between the
dpy-i and the time that flag 3 is checked.

   Subroutines  for tracking the  light pen can  be found on the
"filecase" tape.







































                >>13<<d                                	Color Display

   The color scope is used as  an on-line output device for  the
PDP-1.   The  cathode  ray  tube has  only  a  short persistence
phosphor.  Some characteristics of the display are ---

        512 by 512 addressable locations
        Plots up to 10,000 points per second
        Random point plotting
        Origin may be at one of four points under control of
                each display instruction
        Brightness of each color may be independently
                controlled to one of 16 levels

   The color scope is not operated with the ivk instruction. The
display  does not need to be  assigned, and can be operated from
any console at any time.

   The color scope is  normally left off when  not in use.   The
scope  should be turned on several  minutes prior to using it by
pushing the ON switch.  When  finished using the scope,  depress
the  OFF switch  and hold  it down for  a few  seconds until the
click of the hardware powering off is heard.

   There are two instruction that operate the scope.  The  first
is  iot 16  (720016) which sets the color register from A(3-17).
A(3-5) are respectively the red, green and blue enable bits.  If
the  bit is  zero, the beam  is off regardless  of the intensity
specified elsewhere. If one, the beam will be on.  A(6-9) is the
red intensity, where intensity 0 is dimmest and 17 is brightest.
A(10-13) is  green intensity,  and A(14-17)  is blue  intensity.

   Setting  of the color may be done at any time, even while the
scope is displaying a  point.  If the color  is changed while  a
point is being displayed, the display will be affected.

   A  point is  displayed by  an iot  cw17 (72cw17) instruction.
A(0-8) indicates the horizontal or X coordinate and I(0-8) gives
the vertical or Y coordinate. A and I remain unchanged after the
iot instruction.  The low two bits of "c", instruction bits 7-8,
determine  the centering of the  display and are interpreted the
same as for the non-color scope.

   The high order bit of "c", instruction bit 6, determines  the
length of time the scope will take to display the point.  If the
bit is zero it will take 100 microseconds, and if the bit is one
it will take 250 microseconds. A problem in using the faster iot
is that widely separated points displayed sequentially may  show
noticeable distortion in position.

   No  iot to the color scope waits.   An iot to display a point
will be ignored if the scope  is not finished with the  previous
display. If "w", instruction bit 11, is one, the iot instruction
will skip only if the scope was indeed ready to display a point,
and  will  not  skip  if  the scope  was  busy.   Thus  a common
programming sequence is iot 117, jmp .-1 which will  effectively
wait until the point is accepted before continuing. If bit 11 is
zero, the instruction will never skip.








                >>13<<>>12<<                                
	Buttons and Switches

   Four consoles of nine buttons  and nine switches each can  be
connected  to  the  PDP-1 to  facilitate  communications between
users and  the  machine.   Two  standard  panels  are  currently
available,  each of which  has a set of  buttons and switches on
it.  Either or both of these  may quickly be replaced by  inputs
from  user I/O equipment.  However, the two panels (0 and 1) are
the usual configuration.

   The  button  and  switch  states  are  read  into  I  by  the
instruction,  rbt ("read buttons" = iot  x237).  This will set a
bit in I for each button or switch which is on.  Buttons go into
I(0-8),  and switches into I(9-17).  The x field of the instruc-
tion  determines  which  of  the  four  panels  is  being  read.


          panel 0 = rbt
          panel 1 = rbt 400
          panel 2 = rbt 1000
          panel 3 = rbt 1400

   There  is also a way to  make the timesharing system signal a
program when any button or switch  changes.  See part 5 of  this
Instruction Manual.




	Knobs

   Four consoles of four analog devices each can be connected to
the computer.  Two consoles with  four knobs each are  currently
connected.

   These  may be replaced  by inputs from  external equipment by
simply changing plugs. In the cable is a reference voltage which
is nominally -10 volts. When triggered by a ckn instruction, the
digital to analog converter measures the ratio of input  voltage
to reference voltage and puts this fraction in I[10-17].  In the
case of the  knobs, a reading  of zero means  the knob is  fully
counter-clockwise,  while 377 means that  it is fully clockwise.

   The ckn  instruction  ("check  knobs",  =  iot  27)  has  the
following format --


Bit    0  1  2  3  4  5  6  7  8  9 10 11 12 13 14 15 16 17

       1  1  1  0  1  -  -  -  C  C  K  K  0  1  0  1  1  1

        Op.Code 72=iot                        device 27=knobs

                     ignored console knob











                >>13<<g                                	Plotter

	The Calcomp plotter features>>40<<.

	  0.005 inch (0.127 mm) step size
	  300 steps/sec maximum speed
	  30 inch by 120 feet maximum paper size
	  An adapter for 12 inch wide paper rolls
	  Both liquid ink and ball-point pen

   Liquid  ink and ink  pen points suitable  for the plotter are
made by Staedtler under the trademark "Mars".  Standard  Rapido-
graph  points also work.  Pen points and inks are available in a
variety of widths and colors, respectively.  Ball-point pens are
more  convenient  to  use  than liquid  ink,  but  produce lower
quality drawings. Ball-point pens are available from Calcomp. In
addition,  there  are  some  available  with  the  plotter,  for
experimental  use.   Before  using  the  plotter,  have  someone
instruct  you on procedures for setting  up and putting away the
plotter.

   The plotter must be operated in "PRL" mode. A program  enters
this mode by executing the mta 403 instruction, and leaves it by
executing mta 402. While in PRL mode, references to locations  0
through  77 of  core module 0  are illegal.  While  in PRL mode,
capability indices  may be  any number  between 0  and 77.  (The
upper limit is 17 otherwise.)

   The  plotter is assigned  with mta 306 with  AC = 0727NN, and
operated with ivk NN. NN is often chosen as 27.  The plotter  is
operated  with an ivk with  data in the AC.   The AC may contain
three six-bit fields which are processed in the order  A(12-17),
A(6-11),  then A(0-5)  until either  all three  fields have been
used or a field which is zero is encountered. Each six-bit field
has the following format>>40<<.

	0    1    2    3    4    5     A(0-5)
	6    7    8    9   10   11     A(6-11)
	12  13   14   15   16   17     A(12-17)

	up  down +x   -x   +y   -y

   Up  and down  refer to  the pen  position.  Moving  in the +x
direction causes paper to be rolled off the supply reel onto the
floor.   The coordinate system is  right handed, and the maximum
"y" travel is 30 inches.

   It is not  permissible to specify  +x and -x,  +y and -y,  or
"up" and "down" in the same command field.  It is permissible to
specify any other combination of  x, y, and pen motion  desired.

   This  instruction will complete when  the plotter is ready to
accept another command.  The buffering is sufficient to keep the
plotter  running at full speed if  no more than 3.5 milliseconds
elapses from the time the plotter becomes ready. Subroutines for
drawing lines and characters exist in the Relocatable Subroutine
Library.









                >>13<<w                                	Clocks

   The PDP-1  is  equipped  with  numerous  clock  devices,  but
perhaps  the most useful for ordinary purposes are the temporary
clocks and the real-time clock. The temporary clocks can be used
to  cause a process to wait a  specified time, and the real time
clock provides high-resolution timing information.

   The temporary clock ticks 1760 times per minute, or  slightly
less  than 30 ticks per second.   The clock is assigned with mta
306 with AC = 200NN, and used with an ivk NN.  Unlike many other
devices,  the temporary clock  is not limited  to one copy, that
is, any program can be sure of assigning its own clock  whenever
it wishes.

   In  order to wait for  n ticks of the  clock a program should
load the AC with -(n+1) and execute a clock ivk.  At the end  of
the delay, the program will resume, with AC = 0.  If the initial
AC is >>40<<> -1, the  instruction will complete immediately with  the
AC  unchanged.  The following sequence  would cause a 1/5 second
delay in program execution (providing  the clock be assigned  on
index 6)>>40<<.

   lan 7    /load AC with -(6+1)
   ivk 6

   The  real time clock is usually  read by the mta 103 instruc-
tion, which reads the high 18 bits of the time register into the
AC  and the low 18  bits into the IO.   Any program may read the
clock in this manner at any  time.  This clock ticks once  every
100  microseconds,  but  the  36-bit counter  takes  79  days to
overflow. Thus, it provides an accurate time base for almost any
program application.

   There  is a program  "time" on public tape  0 which reads the
clock and displays the date and time on the CRT.






























                >>13<<e                                	Drum Fields

   A drum field is  a 10000 (octal) word  block of medium  speed
memory.  Transfers take place between  the drum and core memory.

   Drum field assignment  and operation is  similar to that  for
I/O devices. Fields are assigned with mta 300 with AC = NN.  The
field is then read or written with ivk NN.

   The contents of the  AC, IO, and W  registers required for  a
transfer is as follows>>40<<.


     A    | ///////////|      count   | W| 0 0 0 0|
           0         5 6          12 13 14  17

     I    | ///////////|  drum address| 0 0 0 0 0|
           0         5 6          12 13     17

     W    | /////|         core address         |
           0   2 3                          17

   The  core address for  the transfer is  specified in W(3-17),
the drum address  in I(6-17), and  the word count   (plus 20  if
writing)  in A(6-17).  Note that the drum address and word count
must be multiples of 40 octal words and hence will always  leave
I(13-17) zero. If A(13) is zero, data will be read from the drum
into core>>40<<, if one, data will be written onto the drum.  A(14-17)
is ignored.

   The  count will  always be  interpreted as  a multiple  of 40
words, and, if zero, all 4K words will be transferred. Transfers
are performed mod 10000 octal, so that if a transfer attempts to
reference data beyond the end of the field, the references  will
"wrap around" to the beginning of the same field. A transfer may
not cross a core boundary however. The core address need not  be
a  multiple  of  40 words.   The  instruction will  skip  if the
transfer was successful. The contents of the registers are never
changed.

   WARNING  - ET's text buffer is  kept on drum fields on C-list
index 2 and following (as many as necessary, but many texts need
only  field 2).  Writing  on these fields  can destroy the text.
Fields used for  temporary storage by  programs are often  given
numbers around 13 to 15.





















                >>13<<x                                	Microtapes

   The PDP-1 has four microtape (DECtape) transports.

   WARNING  -  Most  microtape operations  are  executed  by the
Microtape File System  (see memo  PDP-42), and  most tapes  have
data  stored  on them  in  a format  known  to the  File System.
Programmers that use microtapes  directly should be  exceedingly
careful,  since writing on  tapes can destroy  files or even the
tape directory.  Scratch  tapes exist,  have appropriate  labels
affixed, and are provided for those who would like to test their
tape programs.

   People wishing  their own  microtapes for  use on  the  PDP-1
should  purchase them UNFORMATTED from DEC or another vendor.  A
special tape marking  program is  used to format  the tape  into
1102  (octal)  blocks numbered  0  through 1101,  each  of which
contains 400  (octal) 18.-bit  words.  These  tape markings  are
compatible  with the DEC standard markings  for the PDP-1, 4, 6,
7, 9, 10 and 15.

            Mechanical operation of the tape drives

   There are four major states of a tape drive. The first  state
is  OFF.  When a  tape  is in  this  state, the  motors  are not
operating and tapes may be  mounted or dismounted. State two  is
manual  mode.  In this mode the  drive is under external control
and tape may  be wound  forward or in  reverse by  the "fwd"  or
"rev"  buttons respectively. The  third state is automatic mode,
which will light the  light above the  auto/run switch. In  this
state the tape is not moving but may at any time begin moving by
command from the CPU. Write permit  may be turned on by  pushing
the write/stop switch to write position for a moment, which will
cause the light above the switch to turn on. If write permit  is
not  on, the hardware will not allow  the tape to be written on,
but will allow read operations to occur. State four is when  the
computer  is actively spinning the  tape, during which time none
of the front panel controls will have any effect.




























                >>13<<>>60<<                                                Program operation of microtapes

   Tape units are  assigned with the  instruction mta 306,  with
the  AC containing 000UNN, and are operated with the instruction
ivk NN.  U specifies the transport number (0 to 3).  NN is often
chosen as 16.

   The  ivk NN instruction will rewind the tape or transfer data
between core and  the tape  as specified by  A, I  and W,  whose
format is illustrated below>>40<<.

     A     | 0 0 0|     count    | 0 0 T C C| 1 1 0|
            0   2 3           9 10     14 15 17

     I     |     tape address   | 0 0 0 0 0 0 0 0|
            0                 9 10           17

     W     | /////|     core address   | 0 0 0 0 0|
            0   2 3                12 13     17

   The core address for the transfer is specified by W(3-17) and
must be a multiple of 40 words, hence W(13-17) will be zero. The
I  register  contains the  starting  tape address  which  is the
initial block number multiplied  by 400.  If  one thinks of  the
tape  as containing 1102x400 words, the tape address is equal to
the desired initial word, which must be a multiple of 400.   The
AC contains the number of words to be transferred, which must be
a multiple of 400, plus other control information. (A word count
of  zero  will be  interpreted  as 400,  however.)   The control
information is as follows>>40<<.

CC = 00   read from tape into core
     10   write from core onto tape
     01   rewind tape to beginning>>40<<,
          program will wait until beginning reached.
     11   rewind tape to beginning but don't
          wait for beginning to be reached.  Any
          subsequent tape instruction will override
          this command and commence immediately.

For example -
        AC = 406 will read one block
        AC = 426 will write one block.
        AC = 16 will rewind and wait.
        AC = 36 will rewind and proceed.


   Consecutive tape blocks  are transferred between  consecutive
areas  of  core.   All 400  words  of  each tape  block  must be
transferred to or from a single  core module.  If more than  one
block  is transferred, different blocks may be in different core
modules.  For example, starting  a two block  tape copy at  core
address  07400 is acceptable, but starting at core address 07500
is not, as it would require the last 100 words be written across
a core boundary.

   In  all cases where the tape is to be used only on the PDP-1,
the T bit, A(12), should be zero.  If tapes from other  computer
installations are used on the PDP-1, see below for a description
of translation.  If all  data was successfully transferred,  the






                >>13<<	                                instruction  will skip.  A(0-11) will be zero, and A(12-17) will
be unchanged.  W will contain one plus the highest core  address
transferred.  The IO will contain one plus the last tape address
transferred.

   If the  transfer  was not  successful,  A(0-11) will  be  the
number of words remaining to be transferred, including the block
which was in error. The IO will contain the tape address of  the
block  in error.  The W will have  an error code which is one of
the following>>40<<.

        0   tape unit is not in automatic status
        1   block cannot be found (probably bad tape)
        2   illegal core address specified
        3   checksum error (data transfer took place anyway)
        4   mark track error (probably bad tape)
        5   data channel error (serious hardware malfunction)
        6   write permit not on.

        Only error 0 can occur for rewind operations.

Translation.
   Microtapes are marked with  block 0 at  the beginning of  the
tape  and block 1101  at the end.  In  order to perform multiple
block transfers  without  stopping the  tape  unnecessarily  and
without  burdening  the user,  the  system translates  the block
numbers given by the  program so that  blocks that are  consecu-
tively numbered (as seen by the program) are two blocks apart on
the  actual  tape.   The  actual  renumbering  is  shown  below.

logical/   0  1  ...  437  440  441  442  ... 1101
physical/  1  3  ...  1077 1101 1100 1076 ... 0

   Setting  the T bit to one will disable translation.  Multiple
block transfers will transfer  consecutive physical tape  blocks
as expected.






























                >>13<<p                                	External register and external levels

   The  instruction  mta  500  (770570) is  used  to  assign and
deassign external levels and the External Register.  The  action
of  the  mta 500  is determined  by  the contents  of the  AC as
follows.  Note that  the external  register and  levels are  not
operated with ivk instructions, and hence the previous consider-
ations regarding C-list indices do not apply.

A[0-5]  Operation

  00    Assign external levels.  For all i, 1 >>40<<< i >>40<<< 7,
        external level i is assigned if A[i+10] = 1.
        For example, to assign external level 2,
        A should contain 40.
        The mta 500 will skip if the assignment is successful,
        i.e. no one else has the level(s) assigned.

  01    Deassign external levels as above.  No skip.

  02    Assign External Register, shared.  Skip if successful,
        i.e. no one else has it assigned as private.

  03    Assign External Register, private.  Skip if successful,
        i.e. no one else has it assigned.

  04    Deassign External Register.  No skip.


     External Levels

     3	Used for temporary hardware connections

     4	External clock

     6	Used for temporary hardware connections

     7	Radio Astronomy antenna


   The PDP-1 External Register is  an 18-bit register which  can
be  loaded and read by the PDP-1  and by I/O devices.  The music
hardware and the 8-bit D>>20<<A converter use the External  Register.
The  External Register must  be assigned before  it can be used.

Instruction        Action

lei (724577)   Load External Register from I.

lea (724677)   Load External Register from A.

rer (724777)   Read External Register into I.














                >>13<<>>16<<                                	Music Hardware

   The music hardware  consists of six  identical channels,  one
per voice. Each channel has a flip-flop which can be loaded from
the accumulator sign bit (A(0)) by the appropriate iot  instruc-
tion.   The rate  at which this  flip-flop is turned  on and off
determines the  pitch of  the note  played by  that voice.   The
volume  level for a given channel is controlled by three bits of
the External Register.  Zero in these bits is the softest, seven
the loudest.

 voice   loudness controlled by
         ext. reg. bits
     0    6-8
     1    9-11
     2   12-14
     3   15-17
     4    0-2
     5    3-5

Instruction        Function

72xn14             A(0) to voice n flip-flop, n=0,1,2,3,4,5
                   A(6-8) is ignored


   A  switch  associated with  each  of channels  0-3 determines
whether the output of that channel  is connected to the left  or
right  inputs of the stereo power  amplifier. Voices 4 and 5 are
connected to the right side. Four degrees of treble roll-off can
be  applied to the left and  right sides independently.  This is
controlled by four toggle switches, two per side.

   See the Music Programs memo,  PDP-43, for information on  the
music compiler and the music player.



	8-bit D>>20<<A Converter

   The  input to the  8-bit digital to  analog converter is bits
10-17 of the External  Register.  The output  will be -10  volts
times  the fraction in  ER(10-17).  The output  appears on a BNC
connector inside bay 10.






















                >>13<<>>56<<                                                                                                                                                         