>MOU MU:/FOR/NOWR
>MOU DU3:/FOR
>BRU /INI MU: DU3:
BRU - Starting Tape 1 on MU0:

BRU -- *WARNING* -- No bad block data file found

BRU - This disk will not contain a hardware bootable system

BRU - End of Tape 1 on MU0:

BRU - Completed

>DMO /USER
DMO -- TT0:    dismounted from DU3:    *** Final dismount initiated ***
23:52:28  *** DU3:  -- Dismount complete
DMO -- TT0:    dismounted from MU0:    *** Final dismount initiated ***
23:52:28  *** MU0:  -- Dismount complete
>MOU DU3:/OVR
>ASN DU3:=SY:
>SET /DEF=[200,200]
>@SYSGEN
>;
>; RSX-11M-PLUS  SYSGEN  BL40
>;
>; COPYRIGHT (c)  1987
>; DIGITAL EQUIPMENT CORP., MAYNARD MA., 01754
>;
>SET /DPRO=[RWED,RWED,RWE,R]
>;
>; To exit from the SYSGEN procedure at any time, type CTRL/Z.
>;
>; If you are unsure of the answer to a question for which a de-
>; fault answer exists, use the default answer.
>;
>;
>;
>;===================================================
>;  Choosing SYSGEN Options      12-AUG-04 at 23:52
>;===================================================
>;
>;
>;
>; Every question is preceded by a question number (for example SU010)
>; which you can use to find the explanation of the question in the
>; RSX-11M-PLUS System Generation and Installation Guide.
>;
>; An explanation of every question is also available by pressing
>; the ESC key (or the ALTMODE key) in response to the question.
>;
>; If you are unfamiliar with the SYSGEN procedure, the explanation of
>; each question can be printed automatically before the question. 
>;
>* SU010   Do you always want the explanation printed? [Y/N D:N]: Y
>;
>; SYSGEN always creates saved answer files containing your responses
>; to the SYSGEN questions:
>;
>;    SYSGENSA1.CMD     Setup questions, Executive options
>;    SYSGENSA2.CMD     Peripheral configuration
>;    SYSGENSA3.CMD     Nonprivileged task builds
>;
>; You should perform a PREPGEN first to create saved answer files, and
>; then perform a SYSGEN, specifying those saved answer files as input
>; to the Executive, peripheral, and nonprivileged task build sections.
>;
>; If you have performed a SYSGEN (or PREPGEN) before, you can use the
>; saved answer file created during that SYSGEN as input to this SYSGEN.
>; SYSGEN uses the saved answers as your responses to the Executive
>; questions.
>;
>* SU020   Do you want to use a saved answer file as input for
>*         the Executive options? [Y/N D:N]: 
>;
>* SU040   Do you want to use a saved answer file as input for
>*         the peripheral configuration? [Y/N D:N]: 
>;
>* SU060   Do you want to use a saved answer file as input for
>*         the nonprivileged task builds? [Y/N D:N]: 
>;
>; A PREPGEN allows you to answer all the SYSGEN questions and create
>; saved answer files without actually generating a system:  no MCR
>; commands are executed, no files are deleted, and the Executive is
>; not assembled or built.
>;
>; After you have successfully completed a PREPGEN, you can perform a
>; SYSGEN using the saved answer files from the PREPGEN.  The SYSGEN
>; will then run unattended.
>;
>* SU080   Do you want to do a PREPGEN? [Y/N D:N]: 
>;
>; You should have a disk spinning in a disk drive which is a copy of
>; your distribution kit.  This is your target system disk, the disk on
>; which you will perform the SYSGEN.  This disk should already be
>; mounted with the MOUNT command so that you have access to it.
>;
>; Enter the name of the drive containing this disk in the form ddnn:,
>; i.e., DB2:.
>;
>* SU090   Enter the name of the disk drive containing your
>*         target system disk [ddnn:] [S R:2-5]: DU3:
>;
>ASN DU3:=IN:
>ASN DU3:=OU:
>ASN DU3:=LB:
>ASN DU3:=WK:
>ASN DU3:=TK:
>ASN DU3:=BC:
>ASN DU3:=LI:
>ASN DU3:=OB:
>ASN DU3:=EX:
>ASN DU3:=MP:
>;
>; You can:
>;
>;    o  do a complete SYSGEN
>;
>;    o  continue a previous SYSGEN from where you left off
>;
>;    o  do an individual section of SYSGEN
>;
>;
>; A complete SYSGEN consists of:
>;
>;	Choosing Executive options
>;	Choosing Peripheral Configuration
>;
>;	Assembling the Executive and Drivers
>;
>;	Building the Executive and Drivers
>;	Building the Privileged Tasks
>;	Building the Nonprivileged Tasks
>;
>;	Creating the System Image File
>;
>; If you do not choose to do a complete SYSGEN, you can continue
>; a previous SYSGEN from where you left off or do an individual
>; section of SYSGEN.
>;
>* SU120   Do you want to do a complete SYSGEN? [Y/N D:Y]: 
>;
>INS [3,54]MAC/TASK=MACT0 
>INS [3,54]PIP/TASK=PIPT0 
>INS [3,54]LBR/TASK=LBRT0 
>INS [3,54]TKB/TASK=TKBT0 
>INS [3,54]VMR/TASK=VMRT0 
>;
>;
>;
>;======================================================
>;  Choosing Executive Options      12-AUG-04 at 23:53
>;======================================================
>;
>;
>;
>; The answers to the questions in this section are put in the saved
>; answer file [200,200]SYSGENSA1.CMD.
>;
>; You may now enter a comment describing the system you are building.
>; This comment is included in the SYSGENSA1 saved answer file for
>; documentation, and is printed out when the saved answer file is
>; later used as input.
>;
>; Enter a comment for inclusion in the SYSGENSA1 saved answer file.
>; The comment may contain more than one line.  The "V" in the right
>; margin below marks the maximum line length.  When you are done,
>; press RETURN in response to the prompt.
>;                                                                             V
>* Comment [S R:0.-55.]: 
>;
>; RSX-11M-PLUS may be run on the following PDP-11 processors:
>;
>;     11/23-PLUS   (also called MicroPDP-11/23 and 11/23-B)
>;     11/24
>;     11/44
>;	11/53
>;     11/70
>;     11/73        (also called MicroPDP-11/73)
>;     11/83        (also called MicroPDP-11/83)
>;     11/84
>;
>;     LSI-11/73
>;
>* CE010   What is your target processor type? [S R:5.-12. D:"11/70"]: 
>;
>; The following RSX-11M-PLUS Executives may be generated:
>;
>;    o	Full-functionality Executive
>;
>;    o	User-tailored Executive
>;
>;
>; The Full-functionality Executive includes all features of the
>; RSX-11M-PLUS operating system that can be used on your processor.
>;
>;	Executive data space support
>;	User data space support
>;	Task headers out of pool support
>;	Extended logical name support
>;	Supervisor-mode library support
>;	Fast map facility
>;	All DIGITAL-supplied drivers are loadable
>;	ICB pool size of 128. words
>;	Shadow recording support
>;	Disk data caching support
>;	Console driver support
>;	Accounting support
>;	Batch processor support
>;	Queue Manager for spooling
>;	DIGITAL Command Language and alternate CLI support
>;	CTRL/C abort support
>;	High performance FCP
>;	File windows in secondary pool support
>;	Decimal version numbers in file specifications
>;	Virtual terminal support with a default virtual terminal
>;	   unit buffer size of 120. bytes and a maximum of 184. bytes
>;	Character translation support
>;	Terminal driver extended I/O support
>;	Time-out on unsolicited terminal input of 30. seconds
>;
>;
>;	The User-tailored Executive will require you to answer at least
>;	twenty additional questions specifying which standard RSX-11M-PLUS
>;	features you wish to disable.  You should not choose the User-tailored
>;	Executive unless you need to disable specific RSX-11M-PLUS features.
>;
>;
>;	For information and guidelines on generating a User-tailored Executive,
>;	please refer to the RSX-11M-PLUS System Generation and Installation
>;	Guide.
>;
>;	If you do not understand the options presented by the system
>;	generation process when configuring an Executive yourself, please
>;	select the Full-functionality Executive.
>;
>;
>* CE020   Do you want the Full-functionality Executive? [Y/N D:Y]: 
>;
>; Network software provides the capability of simultaneously
>; operating tasks on different systems to establish logical
>; communication links and to exchange data.  This software is
>; not provided with RSX-11M-PLUS, but must be purchased separately.
>;
>; If you choose this option, DCL and alternate CLI support will
>; also be included.
>;
>* CE120   Do you want support for communications products
>*         (such as DECnet, PSI, and LAT)? [Y/N D:N]: Y
>;
>; The system name is an arbitrary six-character name.
>; This should be the same as the DECnet node name, if any.
>;
>* CE130   What is the system name? [S R:0-6 D:"RSXMPL"]: 
>;
>; The IP11 industrial I/O subsystem is a combined software and
>; hardware package used for process control and monitoring in
>; the industrial and manufacturing environment.  It consists
>; of an RSX device driver (IPDRV) and a set of FORTRAN-callable
>; interface routines, used to interface to a variety of hardware
>; I/O modules, including digital sense interrupt, change-of-state,
>; digital output, digital-to-analog converter, and analog-to-digital
>; converter modules.
>;
>; See the IP11 I/O Subsystem Software Installation Guide for
>; information on installing the software.
>;
>* CE264   Do you want IP11 industrial I/O subsystem support? [Y/N D:N]: 
>;
>; The Executive Debugging Tool (XDT) provides a subset of ODT-11
>; that runs as a part of the RSX-11M-PLUS Executive.  This tool
>; allows interactive debugging of Executive modules, I/O drivers,
>; and interrupt service routines.  Selection of this option also
>; includes consistency checks in the dynamic memory routines and
>; the loader.
>;
>; Note:  If your system does not have Executive data space support,
>; XDT will reduce the size of primary pool.  If your system does
>; have Executive data space support, XDT does not affect the size
>; of pool.
>;
>* CE270   Do you want to include XDT? [Y/N D:N]: Y
>;
>; If the system crashes, a message is printed on the crash
>; notification device.  This device must be a paper tape,
>; teletype, or line printer compatible device; that is, the
>; device must transmit a single byte at a time.  Normally,
>; the crash notification device is the console terminal which
>; is always at the default CSR address given below.
>;
>* CE280   Enter the crash notification device CSR
>*         address [O R:160000-177700 D:177564]: 
>;
>; If the system crashes, you can cause all of memory to be written
>; onto a device for later analysis with the Crash Dump Analyzer (CDA).
>;
>; The device on which the crash dump is written must be selected from
>; the following list of devices and cannot be a fixed media device:
>;
>;	DB:      DM:      MM:
>;	DD:      DR:      MS:
>;	DK:      DT:      MT:
>;	DL:      DU:      MU:
>;
>; Note:  Enter both the device and the logical unit number.
>;        For example, MM0: or DL1:.
>;
>* CE290   On what device and unit do you want crash dumps
>*         to be written? [S R:2-6]: MU0:
>;
>; The minimum supported memory size is 128K words for
>; an RSX-11M-PLUS system.  The maximum memory size is 1920K words.
>;
>; This value is only used by VMR when it creates the system image
>; file.  VMR does not allow you to create a partition or load
>; anything beyond the end of memory.  When the system is booted,
>; your actual memory size is calculated and overrides the value
>; you enter here.
>;
>* CE310   Enter memory size (in K words) [D R:128.-1920. D:256.]: 512.
>;
>; The PDP-11 floating point processor is an optional  arithmetic
>; processor.  It  performs   all   floating   point   arithmetic
>; operations and converts data between integer and floating point
>; formats.
>;
>; If you choose floating point processor support, the Executive
>; will dynamically determine whether the processor has a floating
>; point unit or not.
>;
>; If you omit this support, the Executive will not support a
>; floating point unit.
>;
>* CE320   Do you want floating point processor support? [Y/N D:N]: Y
>;
>; RSX-11M-PLUS requires a real-time clock for its operation.  The
>; KW11-P programmable frequency clock, the KW11-L line frequency
>; clock, or the DL11-W line frequency clock/console interface may
>; be used.
>;
>* CE330   Is your system clock programmable (KW11-P)? [Y/N D:N]: 
>;
>; Line frequency is either 50 or 60 Hz.  In the U.S.A., line frequency
>; is always 60 Hz.
>;
>* CE350   Is your line frequency 50 Hz? [Y/N D:N]: Y
>;
>;
>;
>;=============================================================
>;  Choosing Peripheral Configuration      12-AUG-04 at 23:53
>;=============================================================
>;
>;
>;
>; The answers to the questions in this section are put in the saved
>; answer file [200,200]SYSGENSA2.CMD.
>;
>; You may now enter a comment describing the system you are building.
>; This comment is included in the SYSGENSA2 saved answer file for
>; documentation, and is printed out when the saved answer file is
>; later used as input.
>;
>; Enter a comment for inclusion in the SYSGENSA2 saved answer file.
>; The comment may contain more than one line.  The "V" in the right
>; margin below marks the maximum line length.  When you are done,
>; press RETURN in response to the prompt.
>;                                                                             V
>* Comment [S R:0.-55.]: 
>;
>;
>; The RH11 and RH70 MASSBUS controllers are the controllers for
>; the following devices:
>;
>;	DB:	RP04, RP05, RP06 disks
>;	DR:	RM02, RM03, RM05, RM80, RP07 disks
>;	DS:	RS03, RS04 disks
>;	EM:	ML11 semiconductor disk emulator
>;	MM:	TM02, TM03 formatters, TE16, TU16, TU45, TU77 tapes
>;
>* CP0604  How many RH controllers do you have? [D R:0.-15. D:4.]: 0
>;
>;
>;   DK:    controller:  RK11		devices: RK05, RK05F
>;
>; The RK11 cartridge disk drive and control is a complete mass
>; storage system for random access data storage.  The system
>; includes a modular mass storage device utilizing removable
>; disk cartridges and a complete, easy-to-program, control unit.
>; A disk cartridge holds over 2.4 megabytes.  The system is
>; expandable up to 8 drives per controller.  An RK11 includes a
>; controller and the first disk drive.  Optionally, the controller
>; can support up to four RK05F fixed platter drives each with twice
>; the capacity of the standard RK05 drive.
>;
>* CP2204  How many RK11 cartridge disk controllers do you have? [O D:0]: 
>;
>;
>;   DM:    controllers: RK611, RK711	devices: RK06, RK07
>;
>; The RK611/711 is a 3 data surface, removable, random access bulk
>; storage system with a storage capacity of 14 megabytes (RK06) or
>; 28 megabytes (RK07) per pack.  The RK611/711 includes a control
>; unit and the first disk pack drive.  The system is expandable up
>; to eight drives.
>;
>* CP2404  How many RK611/711 disk cartridge controllers do
>*         you have? [O D:0]: 
>;
>;
>;   DL:    controllers: RL11, RLV12	devices: RL01, RL02
>;
>; The  RL11/RLV12 disk subsystem uses a medium performance, RL01/02
>; direct access drive with a single read/write head per surface.
>; Each drive provides 5.2 megabytes (RL01) or 10.4 megabytes (RL02)
>; of storage on a removable, top-loading cartridge.  The subsystem
>; is expandable up to four drives.
>;
>* CP2604  How many RL11/RLV11 disk cartridge controllers do
>*         you have? [O D:0]: 
>;
>;
>;   DP:    controller:  RP11		devices: RP02, RPR02, RP03
>;
>; The RP11 is a complete mass storage system using a magnetic
>; disk pack with 20 data surfaces and a moving read/write head.
>; The RP02 and RPR02 have a capacity of 20 megabytes.  The RP03
>; has a capacity of 41 megabytes.
>;
>* CP2804  How many RP11 disk pack controllers do you have? [O D:0]: 
>;
>;
>; DU:	controllers:	RQDX1, RQDX2, RQDX3, RUX50, RQC25, KDA50, UDA50
>;
>;	devices:	RX33, RX50, RD31, RD51, RD52, RD53, RD54, RC25,
>;			RA60, RA80, RA81, RA82
>;
>;   The total of DU and MU controllers cannot be greater than 10.
>;
>; The MSCP disk controllers are:
>;
>;	RQDX1, RQDX2, RQDX3, RUX50, RQC25, RUC25, KDA50, UDA50
>;
>; These intelligent disk controllers provide enhanced I/O optimization,
>; error correction capability, and, in some cases, dynamic bad block
>; handling.
>;
>* CP3004  How many MSCP disk controllers do you have? [D R:0.-10. D:0.]: 2.
>;
>; The MSCP disk drives are:
>;
>;	RX33, RX50, RD31, RD51, RD52, RD53, RD54
>;	RC25, RA60, RA80, RA81, RA82
>;
>; The RX50 contains two 5.25 inch floppy diskettes with a formatted
>; capacity of 400 kilobytes each.  Count each RX50 (with two
>; diskettes) as two drives.
>;
>; The RD51 is a 5.25 inch fixed media, Winchester technology disk
>; with a formatted capacity of 10 megabytes.
>;
>; The RD52 is a 5.25 inch fixed media Winchester technology disk
>; with a formatted capacity of 31 megabytes.
>;
>; The RD53 is a 5.25 inch fixed media Winchester technology disk
>; with a formatted capacity of 71 megabytes.
>;
>; The RC25 contains a fixed and removable disk on the same spindle
>; with a formatted capacity of 25 megabytes each.  Count each RC25
>; (with two disks:  one fixed, one removable) as two drives.
>;
>; The RA60 is a removable media disk with a formatted capacity of
>; 205 megabytes.
>;
>; The RA80 is a fixed media, Winchester technology disk with a
>; formatted capacity of 121 megabytes.
>;
>; The RA81 is a fixed media, Winchester technology disk with a
>; formatted capacity of 456 megabytes.
>;
>; Enter the total number of MSCP disk drives in your system.
>;
>* CP3008  How many MSCP disk drives do you have? [D R:1.-8. D:1.]: 8.
>;
>;
>; The physical unit number of a drive is the number shown on  the
>; unit number plug (or other indicator) on the drive.
>;
>* CP3036  What is the physical unit number of DU0:? [O R:0-377 D:0]: 
>;
>; The legal characters in a controller specification are:
>;
>;	A and B
>;
>* CP3044  To which DU controller is DU0: connected? [S R:1-1]: A
>;
>;
>* CP3036  What is the physical unit number of DU1:? [O R:0-377 D:1]: 
>;
>* CP3044  To which DU controller is DU1: connected? [S R:1-1]: A
>;
>;
>* CP3036  What is the physical unit number of DU2:? [O R:0-377 D:2]: 
>;
>* CP3044  To which DU controller is DU2: connected? [S R:1-1]: A
>;
>;
>* CP3036  What is the physical unit number of DU3:? [O R:0-377 D:3]: 
>;
>* CP3044  To which DU controller is DU3: connected? [S R:1-1]: A
>;
>;
>* CP3036  What is the physical unit number of DU4:? [O R:0-377 D:4]: 0
>;
>* CP3044  To which DU controller is DU4: connected? [S R:1-1]: B
>;
>;
>* CP3036  What is the physical unit number of DU5:? [O R:0-377 D:5]: 1
>;
>* CP3044  To which DU controller is DU5: connected? [S R:1-1]: B
>;
>;
>* CP3036  What is the physical unit number of DU6:? [O R:0-377 D:6]: 2
>;
>* CP3044  To which DU controller is DU6: connected? [S R:1-1]: B
>;
>;
>* CP3036  What is the physical unit number of DU7:? [O R:0-377 D:7]: 3
>;
>* CP3044  To which DU controller is DU7: connected? [S R:1-1]: B
>;
>;
>; Enter the vector address for this controller.  This vector address
>; can be changed after the SYSGEN by using the VMR CON SET command.
>;
>* CP3068  Enter the vector address of DUA [O R:60-774 D:154]: 
>;
>; Enter the CSR address for this controller.  This CSR address can
>; be changed after the SYSGEN by using the VMR CON SET command.
>;
>* CP3072  What is its CSR address? [O R:160000-177700 D:172150]: 
>;
>;
>; Enter the vector address for this controller.  This vector address
>; can be changed after the SYSGEN by using the VMR CON SET command.
>;
>* CP3068  Enter the vector address of DUB [O R:60-774]: 354
>;
>; Enter the CSR address for this controller.  This CSR address can
>; be changed after the SYSGEN by using the VMR CON SET command.
>;
>* CP3072  What is its CSR address? [O R:160000-177700]: 160334
>;
>;
>;	MU:	controllers:	TK50, TU81, TU81E, TQ81E
>;
>; The TMSCP tape controllers are:
>;
>;	TK50, TU81, TU81E, TQ81E
>;
>;
>* CP3404  How many TMSCP tape controllers do you have? [D R:0.-8. D:0.]: 1
>;
>;
>; The physical unit number of a drive is the number shown on  the
>; unit number plug (or other indicator) on the drive.
>;
>* CP3436  What is the physical unit number of MU0:? [O R:0-377 D:0]: 
>;
>;
>; Enter the vector address for this controller.  This vector address
>; can be changed after the SYSGEN by using the VMR CON SET command.
>;
>* CP3468  Enter the vector address of MUA [O R:60-774 D:260]: 
>;
>; Enter the CSR address for this controller.  This CSR address can
>; be changed after the SYSGEN by using the VMR CON SET command.
>;
>* CP3472  What is its CSR address? [O R:160000-177700 D:174500]: 
>;
>;
>;   CR:    controllers: CM11, CR11
>;
>; The CR11 card reader reads EIA standard 80-column punched data
>; cards at  300  cards  per  minute.  It uses a riffle-air and a
>; vacuum-pick mechanism to move the cards.  The CM11-F reads 80-
>; column mark-sense cards, which can have punched holes, at  285
>; cards per minute.
>;
>* CP4004  How many CM/CR11 card readers do you have? [O D:0]: 
>;
>;
>;   CT:    controller:  TA11		device:  TU60
>;
>; The  TA11  magnetic  tape  cassette  system  is  a  dual-drive,
>; reel-to-reel  unit  designed  to  replace  paper tape.  Its two
>; drives  run  non-simultaneously   using   proprietary   Digital
>; Equipment   Corporation   Philips-type   cassettes.   The  TA11
>; includes  a  control unit and a dual tape transport.
>;
>* CP4204  How many TA11 dual cassettes do you have? [O D:0]: 
>;
>;
>;   MS:    controllers: TS11, TU80, TSV05, TK25
>;
>; The TS11, TU80, and TSV05 are 1/2 inch 1600 bpi tape subsystems
>; and the TK25 is a cartridge tape subsystem.
>;
>* CP4404  How many TS11/TU80/TSV05/TK25
>*         magtape controllers do you have? [O D:0]: 
>;
>;
>;   DT:    controller:  TC11		device:  TU56
>;
>; The TC11 is a dual-unit bidirectional magnetic-tape transport
>; system for auxiliary data storage.
>;
>; The system stores information at fixed  positions  on  magnetic
>; tape  as  in magnetic disk or drum storage devices, rather than
>; at unknown or variable positions as  in  conventional  magnetic
>; tape systems.
>;
>; A DECtape system consists of up to 4 dual transports, a control
>; unit  (which will buffer and control information for up to four
>; dual transports).  A TC11  includes  a  control  unit  and  the
>; first dual tape transport.
>;
>* CP4604  How many TC11 DECtape controllers do you have? [O D:0]: 
>;
>;
>;   DX:    controller:  RX11		device:  RX01
>;
>; The RX11 is an industry  compatible  disk  storage  system  for
>; flexible (floppy) disks.  An RX11 is capable of controlling two
>; flexible disk drives each having a capacity of  256K bytes.
>;
>* CP4804  How many RX11 disk controllers do you have? [O D:0]: 
>;
>;
>;   DY:    controller:  RX211, RXV21	device:  RX02
>;
>; The RX211 and RXV21 are single or double density flexible (floppy) disk
>; controllers with a storage capacity of 256K bytes (single  density)  or
>; 512K bytes (double density).  One controller is capable of  controlling
>; two drives.
>;
>* CP5004  How many RX211/RXV21 disk controllers do you have? [O D:0]: 
>;
>;
>;   DD:    controller:  DL11		device:  TU58
>;
>; The TU58 driver interfaces with  the  3M  DC-100A  tape
>; cartridge drive and  controller units via a parallel to ser-
>; ial DL11 converter at baud  rates  up  to  9.6K.   Data  is
>; stored  on  the media on two parallel tracks recorded in the
>; same direction.  The tape is preformatted into 2048 physical
>; records of 128 bytes each.  Access to these physical records
>; is by groups of four corresponding to a standard  DEC  block
>; of 512 bytes.
>; 
>* CP5204  How many TU58 controllers do you have? [O D:0]: 
>;
>;
>;   LP:    controllers: LA180, LN01, LP11, LS11, LV11
>;          devices:     LA180, LN01, LP01, LP02, LP04, LP05, LP06,
>;                       LP07,  LP14, LP25, LP26, LP27, LS11, LV01
>;
>; The LP11 is a high-speed impact line printer with a rotating drum
>; or band.  It is available in a variety of models, with and without
>; lowercase characters.
>;
>; The LS11 line printer is a medium-speed impact dot-matrix line
>; printer.  It prints at a rate of 165 characters per second at
>; 10 characters per inch with up to 132 characters per line.
>;
>; The LA180 DECprinter is similar to the LS11 with the exception
>; that it prints at the rate of 180 characters per second.
>;
>; The LV11 is a high-speed electrostatic printer-plotter that prints
>; at a rate of 500 lines per minute.  Only the print option is
>; supported under RSX-11M-PLUS.
>;
>* CP5404  How many LP/LS/LV11/LA180 line printers do you have? [O D:0]: 1
>;
>; If a task tries to access the line printer when the device is not
>; ready, a message saying the line printer is not ready is printed
>; on the console terminal.  This message is repeated every n seconds,
>; where n is your response to this question, for as long as the line
>; printer remains not ready.
>;
>; Enter zero to disable this feature and suppress the messages.
>;
>* CP5408  Enter the number of seconds between
>*         line printer-not-ready messages [D R:0.-255. D:15.]: 30.
>;
>; Enter the vector address for this line printer.  This vector address
>; can be changed after the SYSGEN by using the VMR CON SET command.
>;
>* CP5468  Enter vector address of the next line
>*         printer [O R:60-774 D:200]: 
>;
>; Enter the CSR address for this line printer.  This CSR address can
>; be changed after the SYSGEN by using the VMR CON SET command.
>;
>* CP5472  What is its CSR address? [O R:160000-177700 D:177514]: 
>;
>; Here is a table of the valid line printer types and their
>; characteristics:
>;
>;      printer                # of    lines per    supports
>;       type     controller  columns    minute    optimization
>;
>;       LA180     LA180        132          150      no
>;       LN01      LN01         132          600      NA
>;       LP01      LP11-F/H      80     170-1110     yes
>;       LP02      LP11-J/K     132     170-1110     yes
>;       LP04      LP11-R/S     132         1110     yes
>;       LP05      LP11-V/W     132          300      no
>;       LP06      LP11-Y/Z     132      460-600      no
>;       LP07      LP11-G       132         1200      no
>;       LP14      LP11-C/D     132      660-900      no
>;       LP25      LP11-A/B     132      215-300      no
>;       LP26      LP11-E       132      445-600      no
>;       LP27      LP11-U       132     800-1200      no
>;       LS11      LS11         132       60-200      no
>;       LV01      LV11         132          500     yes
>;
>; The printer type is used to set two characteristics in the UCB:
>;
>;    o  Column or buffer width
>;
>;       This is settable in VMR or MCR with the SET /BUF command.
>;
>;
>;    o  Fast line printer support
>;
>;       This is an optimization performed by the driver to eliminate
>;       unnecessary print cycles.  This characteristic is not settable
>;       in VMR or MCR.
>;
>;       If you specify the wrong printer type and the driver performs
>;       the optimization for a printer that does not support it, you
>;       will occasionally lose a line of a listing when the printer
>;       is taken off line.
>;
>;       If you specify the wrong printer type and the driver does not
>;       perform the optimization for a printer that supports it, the
>;       printer will run a little slower than it would with the
>;       optimization, but there will be no other adverse effects.
>;
>; If you do not know the correct printer type for your printer, take
>; the default.  This will give you a 132-column printer without fast
>; printer optimization.  Once your system is running, you can change
>; the number of columns if necessary with the MCR SET command.
>;
>* CP5480  Enter line printer type for LPA [S R:4-5 D:"LP25"]: 
>;
>; If this line printer has both uppercase and lowercase characters,
>; answer Yes to this question.  If it only has uppercase characters,
>; answer No.  Your answer determines the initial setting for
>; lowercase character conversion on this printer.  You can change
>; this at any time by using the MCR SET /LOWER command.
>;
>* CP5484  Does LPA have lowercase characters? [Y/N D:N]: 
>;
>;
>;   MT:    controllers: TM11, TMA11, TMB11   devices: TE10, TU10, TU10W, TS03
>;
>; The  TM/TMA/TMB11 is a magnetic tape system ideally suited  for
>; writing,  reading,  and  storing  large  volumes  of  data  and
>; programs in a serial manner.  The system reads  and  writes  in
>; industry-compatible format. TU10 drives support 10.5-inch reels
>; containing up to 2400 feet of tape upon which over 180 million
>; bits of data can be stored on high density 9-track tape.  TS03
>; drives support 7-inch reels containing up to 600 feet of tape in
>; high density 9-track format.  TU10W drives are compatible with
>; TU10 drives except they operate only on 800 bpi, 9-track tape.
>;
>* CP5604  How many TM/TMA/TMB11 magtape controllers do you have? [O D:0]: 
>;
>;
>;   PP:    controller:  PC11
>;
>; The PC11 is  a  high  speed  paper  tape  reader/punch  that  is
>; capable of reading eight-hole, unoiled, perforated paper tape at
>; 300 characters per second, and punching tape  at  50  characters
>; per second.
>;
>* CP5804  How many PC11 paper tape reader/punches do you have? [O D:0]: 
>;
>;
>;   PR:    controller:  PR11
>;
>; The PR11 is  a high speed paper tape reader that is capable  of
>; reading   eight-hole  unoiled  perforated  paper  tape  at  300
>; characters per second.
>;
>;
>* CP6004  How many PR11 paper tape readers do you have? [O D:0]: 
>;
>;
>;   LA:    controller:  LPA11
>;
>; The LPA11 lab peripheral accelerator is a real-time subsystem which
>; interfaces to the PDP-11 family of computers.  The system consists
>; of the LPA11, up to 2 A/D converters, a programmable real-time
>; clock, a D/A converter, and up to five digital I/O modules.
>;
>* CP6204  How many LPA11 lab subsystems do you have? [D R:0.-16. D:0.]: 
>;
>;
>;   TT:    controllers: DL11, DLV11    controller mnemonic: YL
>;
>; The DL11/DLV11 series of asynchronous single line interfaces handle
>; full or half-duplex communication between a wide variety of serial
>; communication channels and a PDP-11 computer.
>;
>; SYSGEN automatically sets up the data bases for all mandatory
>; DL11/DLV11s.  (For each processor in the system, there must be a
>; DL11/DLV11; these are mandatory.)  Answer the next question with
>; the number of additional DL11/DLV11s in your system.
>;
>; Note:  Enter only the number of DL11s used as terminal interfaces.
>; Do not include any DL11s used as controlers for the TU58 DECtape II.
>;
>* CP6804  Enter number of additional DL11/DLV11 line interfaces [O D:0]: 
>;
>; The terminal types supported by RSX-11M-PLUS SYSGEN are:
>;
>;	ASR33       LA12        VT05B
>;	ASR35       LA30P       VT50
>;	            LA30S       VT52
>;	DTC01       LA34        VT55
>;	            LA36        VT61
>;	KSR33       LA38        VT100
>;	            LA50        VT101
>;	            LA100       VT102
>;	            LA120       VT105
>;	            LA180S      VT125
>;	            LA210       VT131
>;	            LN03        VT132
>;	            PC3xx       VT2xx
>;
>* CP6832  Enter terminal type for YLA [S R:4-6 D:"LA120"]: VT100
>;
>;
>;   TT:    controller:  DH11           controller mnemonic: YH
>;
>; The DH11 multiplexer connects the PDP-11 with 16 asynchronous
>; serial communications lines operating with individually
>; programmable parameters.  These parameters are:
>;
>;	transmitter speed (baud)
>;	receiver speed (baud)
>;
>* CP7004  Enter number of DH11 asynchronous line
>*         multiplexers [D R:0.-16. D:0.]: 
>;
>;
>;   TT:    				   controller mnemonic: YV
>;
>;   	controllers: DHU11, DHV11, CXA16, CXB16, CXY08
>;
>;
>; These multiplexers connect the PDP-11 with up to
>; 16 (DHU11, CXA16, CXB16) or 8 (DHV11, CXY08) 
>; asynchronous serial communications lines operating with
>; individually programmable parameters.  These parameters are:
>;
>;	transmitter speed (baud)
>;	receiver speed (baud)
>;
>; Modem control is available with the DHU11, DHV11 and CXY08.
>; The CXA16 and CXB16 do not support modem control.  Use the VMR 
>; or MCR SET /REMOTE commands in order to enable dialup lines.
>;
>* CP7104  Enter number of DHU11/DHV11/CXA16/CXB16/CXY08 (YV:-type)
>*         asynchronous line multiplexers [D R:0.-16. D:0.]: 1
>;
>; Support for remote (dial-up) lines:
>;
>; DHU11, DHV11, and CXY08  controllers support modem control.
>; Modem control is not supported by the CXA16 and CXB16.
>;
>; Since it is not possible to tell which YV: controllers in your 
>; configuration might support remote lines, SYSGEN cannot automatically 
>; enable any lines as remote.  You should use the VMR or MCR command 
>; SET /REMOTE command to enable lines as remote.  You may wish to 
>; pause and edit VMRTTY.CMD at the end of this SYSGEN to add those 
>; VMR commands.
>;
>* CP7120  Enter total number of YV: controller dial-up lines [D R:0.-16. D:0.]:
 16.
>;
>; The valid baud rates are:
>;
>;	   75
>;	  110
>;	  134.5
>;	  150
>;	  300
>;	  600
>;	 1200
>;	 1800
>;	 2000
>;	 2400
>;	 4800
>;	 9600
>;	19200
>;
>* CP7128  At which baud rate do you want to answer? [S R:2-5 D:"300"]: 9600
>;
>; The vector address for each YV: controller is assigned from the 
>; floating vector space starting at 300.  The vector address can be 
>; changed after the SYSGEN by using the VMR CON SET command.
>;
>* CP7168  Enter vector address of YVA [O R:300-770]: 300
>;
>; The CSR address for each YV: controller is assigned from the floating
>; address space starting at 160010.  The CSR address can be changed
>; after the SYSGEN by using the VMR CON SET command.
>;
>* CP7172  What is its CSR address? [O R:160000-177700]: 160440
>;
>; Each DHV11 or CXY08 multiplexer supports up to 8 lines, and
>; each DHU11, CXA16 or CXB16 multiplexer can support up to 16 lines.
>; You can specify less than the maximum allowed by the hardware device,
>; but another SYSGEN will be required to add lines beyond the number 
>; specified in response to this question.  Thus it is advisable to 
>; respond with the maximum allowed by the device.
>;
>* CP7176 How many lines does YVA support? [D R:1.-16. D:16.]: 
>;
>; The terminal types supported by RSX-11M-PLUS SYSGEN are:
>;
>;	ASR33       LA12        VT05B
>;	ASR35       LA30P       VT50
>;	            LA30S       VT52
>;	DTC01       LA34        VT55
>;	            LA36        VT61
>;	KSR33       LA38        VT100
>;	            LA50        VT101
>;	            LA100       VT102
>;	            LA120       VT105
>;	            LA180S      VT125
>;	            LA210       VT131
>;	            LN03        VT132
>;	            PC3xx       VT2xx
>;
>* CP7184  Enter terminal type for YVA [S R:4-6 D:"VT100"]: 
>;
>;
>;   TT:    controller:  DJ11           controller mnemonic: YJ
>;
>; The DJ11 is a multiplexed  interface  between  16  asynchronous
>; serial  data-communications channels and the PDP-11 UNIBUS. The
>; DJ11 is a unit whose character formats and operating speeds are
>; jumper or strap selectable in groups of four lines.
>;
>* CP7204  Enter number of DJ11 asynchronous line
>*         multiplexers [D R:0.-15. D:0.]: 
>;
>;
>;   TT:    controllers: DZ11, DZQ11, DZV11, DFA01    controller mnemonic: YZ
>;
>; The DZ11/DZQ11/DZV11/DFA01 multiplexers connect the PDP-11 with up to
>; 8 asynchronous serial communications lines operating with individually  
>; programmable parameters.  These parameters are:
>;
>;  Transmitter speed / Receiver speed (baud)
>;
>* CP7404  Enter number of DZ11/DZQ11/DZV11/DFA01 asynchronous line
>*         multiplexers [D R:0.-30. D:0.]: 
>;
>; SYSVMR.CMD, the VMR command file which creates your system image file,
>; contains commands that set the characteristics for each terminal as
>; follows:
>;
>; Terminal type:       as you specified for the controller
>; Buffer width:        80
>; Speed:               300/300 for hardcopy terminals
>;                      9600/9600 for CRTs
>; Lower to upper-
>;   case conversion:   No for hardcopy terminals
>;                      Yes for CRTs
>;
>; If you wish to change these characteristics for your terminals, SYSGEN
>; will allow you to edit SYSVMR.CMD.
>;
>;
>;
>; Intercomputer communication devices consist of the following:
>;
>;	PCL11		full-duplex DMA interprocessor communications
>;			device
>;	DMC11/DMR11	high-speed synchronous serial line interface
>;	DUP11		synchronous serial line interface
>;	DEUNA		Ethernet communications controller
>;
>; Note:  Do NOT include any devices which will be used with DECnet.
>; Those devices should be included when you do your NETGEN.
>;
>* CP7604  Do you have any intercomputer communication devices? [Y/N D:N]: 
>;
>;
>; Enter device mnemonics for any user-supplied drivers.  The driver
>; source files must reside in [11,10] and be named ddDRV.MAC and
>; ddTAB.MAC where dd is the device mnemonic.
>;
>; You may enter the mnemonics on more than one line.  When you have
>; listed all the drivers, press RETURN when asked for the device
>; mnemonic.
>;
>; The device mnemonic must not include a colon.
>;
>* CP9604  Enter device mnemonics for user-supplied drivers [S]: 
>;
>;
>; If you will be adding other devices after this SYSGEN or have
>; included user-supplied devices, you will want to set the highest
>; interrupt vector address high enough to accommodate the vectors for
>; those devices.
>;
>; The highest vector among the devices you specified in this SYSGEN
>; is 374(octal).  This is the default response for this question.
>;
>* CP9632  What is the highest interrupt vector
>*         address? [O R:374-774 D:374]: 774
>;
>;
>;
>;================================================================
>;  Assembling the Executive and Drivers      12-AUG-04 at 23:58
>;================================================================
>;
>;
>;
>; The answers to the questions in this section are put in the saved
>; answer file [200,200]SYSGENSA1.CMD.
>;
>PIP RSXMC3.MAC=RSXMC1.MAC,RSXMC2.MAC
>PIP RSXMC.MAC=RSXMC3.MAC,RSXMC0.MAC
>;
>; Copy the files created by the Executive options and peripheral
>; configuration sections into the correct directories.
>;
>SET /UIC=[1,24]
>PIP [11,10]/NV=[200,200]RSXMC.MAC
>PIP [11,10]/NV=[200,200]SYSTB.MAC
>UFD SY:[11,24]
>PIP [11,24]/NV=[200,200]RSXASM.CMD
>PIP [11,24]/NV=[200,200]DRIVERS.ASM
>;
>;
>; Assembly listings of the Executive modules and the drivers can be
>; generated and stored in a file or printed directly.
>;
>; Generating listings is time-consuming and they are not normally
>; needed, so we recommend you answer No to this question.
>;
>* AE010   Do you want assembly listings of the Executive and
>*         drivers? [Y/N D:N]: 
>;
>ASN NL:=LS:
>;
>;
>; If you are building a specialized system you may wish to edit
>; some of the files which SYSGEN produced before the Executive
>; and drivers are assembled.
>;
>* AE030   Do you wish to pause to edit any files before
>*         assembling? [Y/N D:N]: 
>;
>SET /UIC=[11,24]
>;
>; Now we assemble the Executive and resident drivers.
>;
>PIP *.OBJ;*/DE/NM,*.TTY;*
>;
>TIME
23:59:11 12-AUG-04
>;
>MAC @RSXASM
>;
>; Now we assemble the loadable drivers.
>;
>TIME
00:04:33 13-AUG-04
>;
>MAC @DRIVERS.ASM
>;
>TIME
00:07:26 13-AUG-04
>;
>; Now we build the concatenated object module file for the Executive.
>;
>PIP RSX11M.OBS=*.OBJ
>PIP TTDRV.OBS=*.TTY
>;
>SET /UIC=[200,200]
>PIP /NV=[11,10]RSXMC.MAC
>;
>SET /UIC=[1,24]
>PIP RSXBLD.CMD/PU/NM
>PIP RSX11M.OLB;*/DE/NM
>PIP [200,200]RSXMC.MAC/PU/NM
>;
>; Now we build the Executive library.
>;
>LBR RSX11M/CR:256.::256./-EP=[11,24]RSX11M.OBS
>PIP [11,24]RSX11M.OBS;*,*.OBJ;*/DE
>;
>; Now we build the terminal driver library.
>;
>LBR TTDRV/CR:40.:392.:128.=[11,24]TTDRV.OBS
>PIP [11,24]TTDRV.OBS;*,*.TTY;*/DE
>SET /UIC=[200,200]
>;
>;
>;
>;==============================================================
>;  Building the Executive and Drivers      13-AUG-04 at 00:08
>;==============================================================
>;
>;
>;
>; The answers to the questions in this section are put in the saved
>; answer file [200,200]SYSGENSA1.CMD.
>;
>;
>; Allocate space to be used later for the system image file.
>;
>SET /UIC=[1,54]
>PIP RSX11M.TMP/CO/BL:1026.=NL:
>;
>SET /UIC=[200,200]
>;
>SET /UIC=[1,24]
>SET /UIC=[200,200]
>SET /UIC=[1,54]
>PIP SYSVMR.CMD=[200,200]SYSVMR.CMD,VMRTTY.CMD
>;
>SET /UIC=[200,200]
>;
>; At this point, you can edit:
>;
>;	the Executive task-build command files in [200,200]
>;	the driver task-build command files in [200,200]
>;	the privileged task task-build command files in [1,24]
>;	SYSVMR.CMD in [1,54]
>;
>; In most cases there is no need to edit the task-build command files.
>; However, you may want to tailor SYSVMR for your system.
>;
>* BE030   Do you want to pause to edit any files before
>*         task-building? [Y/N D:N]: 
>;
>SET /UIC=[1,24]
>PIP [1,24]/NV/NM=[200,200]RSXBLD.CMD,RSX11M,DSP11M,LDR11M
>PIP [1,24]/NV=[200,200]DIR11M.CMD,DR211M,DIRCOM,DR2COM,DIR
>PIP [1,24]/NV=[200,200]DR311M.CMD,DR411M,DR3COM,DR4COM
>PIP [1,24]/NV=[200,200]VEC11M.CMD,DCM11M,VECCOM
>;
>; Now we build the Executive.
>;
>TIME
00:09:02 13-AUG-04
>;
>TKB @RSXBLD
>;
>; Now we build the loadable drivers
>;
>TIME
00:10:23 13-AUG-04
>;
>TKB @[200,200]DRIVERS.BLD
>;
>TIME
00:11:08 13-AUG-04
>SET /UIC=[200,200]
>;
>;
>;
>;=========================================================
>;  Building the Privileged Task      13-AUG-04 at 00:11
>;=========================================================
>;
>;
>;
>; The answers to the questions in this section are put in the saved
>; answer file [200,200]SYSGENSA1.CMD.
>;
>;
>; Maps of the privileged tasks can be generated and stored in a file
>; or printed directly.
>;
>; Maps of the privileged tasks are not normally needed, so we
>; recommend you answer No to this question.
>;
>* BP040   Do you want the maps of the privileged tasks? [Y/N D:N]: 
>;
>ASN NL:=MP:
>;
>SET /UIC=[1,24]
>;
>TIME
00:11:13 13-AUG-04
>;
>TKB @SAVBLD
>;
>TIME
00:11:31 13-AUG-04
>;
>ASN LB:=OU:
>SET /UIC=[200,200]
>;
>;
>;
>;============================================================
>;  Rebuilding Supplied System Tasks      13-AUG-04 at 00:11
>;============================================================
>;
>;
>;
>; The answers to the questions in this section are put in the saved
>; answer file [200,200]SYSGENSA3.CMD.
>;
>;
>; All nonprivileged and vectored privileged system tasks are supplied 
>; already task-built and can be found in the library UFD on the target 
>; system disk.  It is not normally necessary to rebuild these supplied
>; system tasks although you may wish to do so, for example if one of 
>; them has been patched.
>;
>* BN010   Do you want to rebuild any system tasks? [Y/N D:N]: Y
>;
>; You may now enter a comment describing the system you are building.
>; This comment is included in the SYSGENSA3 saved answer file for
>; documentation, and is printed out when the saved answer file is
>; later used as input.
>;
>; Enter a comment for inclusion in the SYSGENSA3 saved answer file.
>; The comment may contain more than one line.  The "V" in the right
>; margin below marks the maximum line length.  When you are done,
>; press RETURN in response to the prompt.
>;                                                                             V
>* Comment [S R:0.-55.]: 
>;
>; FCSRES is a resident library of commonly used FCS routines.  
>; Tasks can be built to map to the FCS routines in FCSRES instead of 
>; including the FCS routines in their task image.  This saves physical 
>; memory because the many separate copies of the FCS routines in 
>; different task images are replaced by one copy in the library which 
>; all the tasks use.  
>;
>; FCSFSL uses the FCSRES library mapped as a supervisor-mode library.
>; In addition to the saving of physical memory, the supervisor-mode 
>; library also saves virtual address space since the FCS routines
>; are mapped using the supervisor mode APRs.  This frees user-mode 
>; virtual address space for the application task.  This can be used
>; to reduce overlay activity, for example.
>;
>; SYSGEN can build many of the system tasks to use the FCS resident
>; libraries if you desire.  If you answer "Yes" to the following 
>; question SYSGEN will use FCSFSL and FCSRES wherever possible.  If you
>; answer "No" to this question SYSGEN will only use FCSFSL or FCSRES 
>; when you explicitly include it in the task specification.
>;
>* [Y] BN012	Use the FCSRES and FCSFSL libraries? [Y/N]: Y
>;
>; The following supplied system tasks and utilities can be rebuilt at this time
:
>;
>; The letters "R" and "F" in parentheses following the task name indicate that
>; versions may be built to use FCSRES and FCSFSL respectively.
>;
>; ACC (R&F)  	CRP      	HEL (R&F)      	MTA      	SLP (R&F)
>; ACD  	DCL      	HRC      	PAT (R&F)      	STK (F)
>; ACNT (R&F)  	DLD      	ICM (R&F)      	PIP (R&F)      	SYL (R&F)
>; ACS (R&F)  	DMO      	INI      	PMD (R&F)      	TDX
>; BAD  	DMP (R&F)      	INS      	PMT      	TKB (R&F)
>; BOO  	DSC      	IPP (R&F)      	PSW      	TKN
>; BRO  	DTE      	IOX (R&F)      	QMG (R&F)      	UFD
>; BRU  	EDI (R&F)      	LBR (R&F)      	QMGCLI      	UML
>; BYE  	EDT (R&F)      	LOA      	QMGPRT      	UNL (R&F)
>; CDA (R&F)  	ELI (R&F)      	LPP (R&F)      	RCT      	VFY (R&F)
>; CFL (F)  	ERL      	MAC (R&F)      	RMD      	VMR
>; CMP (R&F)  	FLX (R&F)      	MCD      	RPT (F)      	XDT
>; CON  	FMT      	MCR      	SHA      	ZAP (R&F)
>; COT (R&F)  	FTB (R&F)      	MFT      	SHF      	
>; CRF (R&F)  	FXR      	MOU      	SHU      	
>;
>; Press ESC for the list of the nonprivileged utilities and
>; vectored privileged system tasks that may be rebuilt here.
>;
>; Enter ALL to build all the tasks, using FCSFSL and FCSRES.
>; Enter ALLVAN to build all non-FCSRES and non-FCSFSL tasks.
>; Enter ALLRES to build all the FCSRES tasks.  
>; Enter ALLFSL to build all the FCSFSL tasks.
>;
>; SYSGEN will attempt to use FCSFSL and FCSRES where possible.
>;
>; Enter the task names separated by commas.  You can enter them on
>; more than one line.  When you are done, finish the list with a
>; period or press RETURN in response to the prompt.
>;
>* BN020	Enter task name(s) [S]: ALL
>* BN020	Enter task name(s) [S]: 
>;
>;
>SET /UIC=[1,24]
>SET /UIC=[200,200]
>;
>; Maps of the system tasks can be generated and stored in a file
>; or printed directly.
>;
>; Maps of the system tasks are not normally needed, so we
>; recommend you answer No to this question.
>;
>* BN030   Do you want the maps of the system tasks? [Y/N D:N]: 
>;
>ASN NL:=MP:
>;
>; At this point, you can edit the system task task-build command
>; files in [1,24].  In most cases there is no need to edit these files.
>;
>* BN050   Do you want to pause to edit any files before
>*         task-building? [Y/N D:N]: 
>SET /UIC=[1,24]
>;
>; Now we will build the requested system tasks.
>;
>;
>TKB @ACDBLD
>TKB @BADBLD
>TKB @BOOBLD
>TKB @BROBLD
>TKB @BRUBLD
>TKB @BYEBLD
>TKB @CONBLD
>TKB @CRPBLD
>TKB @DCLBLD
>TKB @DLDBLD
>TKB @DMOBLD
>TKB @DSCBLD
>TKB @DTEBLD
>TKB @ERLBLD
>TKB @FMTBLD
>TKB @FXRBLD
>TKB @HRCBLD
>TKB @INIBLD
>TKB @INSBLD
>TKB @LOABLD
>TKB @MCDBLD
>TKB @MCRBLD
>TKB @MFTBLD
>TKB @MOUBLD
>TKB @MTABLD
>TKB @PMTBLD
>TKB @PSWBLD
>TKB @QCLBLD
>TKB @QPRBLD
>TKB @RCTBLD
>TKB @RMDBLD
>TKB @SHABLD
>TKB @SHFBLD
>TKB @SHUBLD
>TKB @TDXBLD
>TKB @TKNBLD
>TKB @UFDBLD
>TKB @UMLBLD
>TKB @VMRBLD
>TKB @XDTBLD
>TKB @ACCFSLBLD
>TKB @ACNFSLBLD
>TKB @ACSFSLBLD
>TKB @CDAFSLBLD
>TKB @CFLFSLBLD
>TKB @CMPFSLBLD
>TKB @COTFSLBLD
>TKB @CRFFSLBLD
>TKB @DMPFSLBLD
>TKB @EDIFSLBLD
>TKB @EDTFSLBLD
>TKB @ELIFSLBLD
>TKB @FLXFSLBLD
>TKB @FTBFSLBLD
>TKB @HELFSLBLD
>TKB @ICMFSLBLD
>TKB @IPPFSLBLD
>TKB @IOXFSLBLD
>TKB @LBRFSLBLD
>TKB @LPPFSLBLD
>TKB @MACFSLBLD
>TKB @PATFSLBLD
>TKB @PIPFSLBLD
>TKB @PMDFSLBLD
>TKB @QMGFSLBLD
>TKB @RPTFSLBLD
>TKB @SLPFSLBLD
>TKB @STKFSLBLD
>TKB @SYLFSLBLD
>TKB @TKBFSLBLD
>TKB @UNLFSLBLD
>TKB @VFYFSLBLD
>TKB @ZAPFSLBLD
>;
>SET /UIC=[200,200]
>;
>;
>;
>;==========================================================
>;  Creating the System Image File      13-AUG-04 at 00:34
>;==========================================================
>;
>;
>SET /UIC=[1,54]
>;
>PIP RSX11M.TMP;*/DE/NM
>;
>PIP RSX11M.SYS/CO/NV/BL:1026.=RSX11M.TSK
>;
>ASN LB:=SY:
>;
>; Utility tasks stay in utility UFD [3,54].
>;
>; RSX11M.TSK is a backup copy of the Executive you just built.
>;
>;
>; VMR will now initialize the system.
>;
>VMR @SYSVMR

Loading Executive data space
Data space loading completed
VMR -- *DIAG*-Installed tasks or commons may no longer fit in partition
SET /TOP=SYSPAR:-*
VMR -- *DIAG*-Loadable driver larger than 4K
LOA TT:
VMR -- *DIAG*-Installed tasks or commons may no longer fit in partition
SET /TOP=DRVPAR:-*
SECPOL 117734 00177100 00100000  SEC POOL
SYSPAR 117670 00277100 00163200  MAIN
       117624 00277100 00110400  RO COM !DIR11M!
       117434 00407500 00005200  TASK   [...LDR]
       117230 00414700 00032200  TASK   [MCR...]
       117024 00447100 00010000  TASK   [TKTN  ]
       116620 00457100 00003200  TASK   [SHF...]
DRVPAR 116540 00462300 00124200  MAIN
       116474 00462300 00006600  RO COM !TTEXT !
       116410 00471100 00020600  RO COM !TTCOM !
       116324 00511700 00034500  DRIVER (TT:)
       116260 00546400 00006200  RO COM !PUCOM !
       115014 00554600 00012600  DRIVER (DU:)
       114460 00567400 00011200  DRIVER (MU:)
       114240 00600600 00001300  DRIVER (LP:)
       114050 00602100 00000100  DRIVER (NL:)
       114004 00602200 00000300  DRIVER (CO:)
       113740 00602500 00002500  DRIVER (VT:)
       113674 00605200 00001300  DRIVER (RD:)
GEN    113630 00606500 03171300  MAIN
...LDR 12.01  117500  SYSPAR 248. 00005200 LB0:-00166347 FIXED
TKTN   07.00  117070  SYSPAR 248. 00010000 LB0:-00174060 FIXED
F11MSG 15.00  111424  GEN    200. 00006200 LB0:-00050326
MTAACP 16.00  111030  GEN    200. 00016200 LB0:-00173731
SHE... 05.01  110560  GEN    200. 00014200 LB0:-00173032
MCR... 06.00  117274  SYSPAR 160. 00032200 LB0:-00172531 FIXED
F11ACP 06.02  113414  GEN    149. 00014400 LB0:-00042030
ERRLOG 05.01  113054  GEN    148. 00055200 LB0:-00172013
PMT... 2.01   112414  GEN    148. 00007100 LB0:-00170121
COT... 2.02   111550  GEN    145. 00013500 LB0:-00175577
HRC... 03.01  111154  GEN    140. 00057400 LB0:-00172302
PMD... 07.03  110704  GEN    140. 00017600 LB0:-00200220
SYSLOG 04.00  112020  GEN    130. 00020400 LB0:-00200502
SHF... 07.00  116664  SYSPAR 105. 00003200 LB0:-00172601 FIXED
RCT... 5.00   112144  GEN    100. 00011500 LB0:-00172565
FXR... 03.01  111300  GEN    100. 00003300 LB0:-00172214
BAP0   04.11  113200  GEN     80. 00047600 LB0:-00045441
QMG... 03.05  112270  GEN     75. 00034500 LB0:-00200250
LP0    06.00  112634  GEN     70. 00016700 LB0:-00177663
ACNT   06.02  111674  GEN     50. 00052400 LB0:-00175150
SHUTUP 04.02  110434  GEN     50. 00015400 LB0:-00173050
...RMD 4.03   002027+ GEN    225. 00041100 LB0:-00174444
...DCL 4.02   002003+ GEN    160. 00056100 LB0:-00171066
...DMO 04.01  002005+ GEN    160. 00017300 LB0:-00170713
...MCR 04.09  002021+ GEN    160. 00040300 LB0:-00173071
...MOU 26.05  002023+ GEN    160. 00045300 LB0:-00172674
...CA. 14.01  002057+ GEN    150. 00025000 LB0:-00173700
...INS 15.00  002017+ GEN    100. 00051200 LB0:-00172456
...SAV 09.00  002053+ GEN    100. 00061000 LB0:-00166674
...UFD 7.00   002061+ GEN    100. 00014300 LB0:-00174072
...ACS 3.01   002035+ GEN     70. 00004100 LB0:-00175541
...ACC 04.00  001775+ GEN     65. 00031300 LB0:-00175060
...SHA 05.01  002055+ GEN     65. 00030500 LB0:-00174766
...AT. 9.0    002011+ GEN     64. 00052000 LB0:-00177277
...INI 23.02  002013+ GEN     60. 00036000 LB0:-00172364
...HOM 23.02  002015+ GEN     60. 00036000 LB0:-00172364
...BRO 07.00  001777+ GEN     50. 00036400 LB0:-00170017
...BYE 05.00  002001+ GEN     50. 00020400 LB0:-00170142
...HEL 04.02  002007+ GEN     50. 00033600 LB0:-00176422
...PIP 17.06  002025+ GEN     50. 00027200 LB0:-00200137
...UNL 5.02   002031+ GEN     50. 00021000 LB0:-00200525
...ACD 2.00   002033+ GEN     50. 00041200 LB0:-00167602
...BOO 02.00  002037+ GEN     50. 00033400 LB0:-00167761
...CON 03.00  002041+ GEN     50. 00130200 LB0:-00170416
...ELI 04.01  002043+ GEN     50. 00031700 LB0:-00176366
...LOA 5.02   002045+ GEN     50. 00037200 LB0:-00172613
...MAG 03.00  002047+ GEN     50. 00036400 LB0:-00170060
...PSW 03.00  002051+ GEN     50. 00015700 LB0:-00055203
YLA	OFL	CPA	CSR=177560	VEC=60	PRI=5
YVA	OFL	CPA	CSR=160440	VEC=300	PRI=5
DUA	OFL	CPA	CSR=172150	VEC=154	PRI=5
DUB	OFL	CPA	CSR=160334	VEC=354	PRI=5
MUA	OFL	CPA	CSR=174500	VEC=260	PRI=5
LPA	OFL	CPA	CSR=177514	VEC=200	PRI=4
CO0:			OFL	DRIVER
TT0:	YLA0:		OFL	DRIVER
TT1:	YVA0:		OFL	DRIVER
TT2:	YVA1:		OFL	DRIVER
TT3:	YVA2:		OFL	DRIVER
TT4:	YVA3:		OFL	DRIVER
TT5:	YVA4:		OFL	DRIVER
TT6:	YVA5:		OFL	DRIVER
TT7:	YVA6:		OFL	DRIVER
TT10:	YVA7:		OFL	DRIVER
TT11:	YVA10:		OFL	DRIVER
TT12:	YVA11:		OFL	DRIVER
TT13:	YVA12:		OFL	DRIVER
TT14:	YVA13:		OFL	DRIVER
TT15:	YVA14:		OFL	DRIVER
TT16:	YVA15:		OFL	DRIVER
TT17:	YVA16:		OFL	DRIVER
TT20:	YVA17:		OFL	DRIVER
VT0:			OFL	DRIVER
RD0:			ONL	DRIVER
DU0:	DUA0:		OFL	DRIVER
DU1:	DUA1:		OFL	DRIVER
DU2:	DUA2:		OFL	DRIVER
DU3:	DUA3:		OFL	DRIVER
DU4:	DUB0:		OFL	DRIVER
DU5:	DUB1:		OFL	DRIVER
DU6:	DUB2:		OFL	DRIVER
DU7:	DUB3:		OFL	DRIVER
MU0:	MUA0:		OFL	DRIVER
LP0:	LPA0:		OFL	DRIVER
NL0:			OFL	DRIVER
POOL=1200:13138.:13138.:1771
>;
>; When you are finished with SYSGEN, software boot in your target
>; system.  Set the date and time, and save the system without any
>; switches to verify that the system is working.  Then save the
>; system again, this time with the /WB switch to make it hardware
>; bootable.
>;
>; The optional SAVE switches are:
>;
>;	/WB			writes the boot block
>;	/SFILE="filename" 	uses "filename" as the startup file
>;	/MOU="mount-switches"	specifies mount switches to be used
>;				when the system volume is mounted
>;
>; For example:
>;
>;	>BOOT [1,54]RSX11M.SYS
>;	XDT: 24
>;
>;	XDT>G
>;	RSX-11M-PLUS V3.0  BL24
>;
>;	>
>;	 TIM 19-APR-85 12:00:00
>;	>SAV
>;
>;	  RSX-11M-PLUS V3.0  BL24   256.K System:"MJTOAD"
>;	>RED DB:=SY:
>;	>RED DB:=LB:
>;	>RED DB:=SP:
>;	>MOU DB:"RSX11MPBL24"
>;	>@DB:[1,2]STARTUP
>;		.
>;		.
>;		.
>;	>* Please enter time and date (HH:MM MM/DD/YY) [S]: ^Z
>;	>@ <EOF>
>;	>SAV /WB
>;
>;	  RSX-11M-PLUS V3.0  BL24   256.K System:"MJTOAD"
>;	>RED DB:=SY:
>;	>RED DB:=LB:
>;	>RED DB:=SP:
>;	>MOU DB:"RSX11MPBL24"
>;	>@DB:[1,2]STARTUP
>;		.
>;		.
>;		.
>;	>* Please enter time and date (HH:MM MM/DD/YY) [S]: 12:01 4/19/85
>;	>TIME 12:01 4/19/85
>;	>ACS SY:/BLKS=1024.
>;	>CON ONLINE ALL
>;		.
>;		.
>;		.
>;	>@ <EOF>
>;	>SET /UIC=[1,54]
>;	>PIP [2,54]*.*;*/DE
>;	>
>;
>; You may wish to edit [1,2]STARTUP.CMD and [1,2]QMGSTART.CMD
>; to reflect your desired initialization operations. 
>;
>SET /UIC=[200,200]
>;
>REM MACT0 
>REM PIPT0 
>REM LBRT0 
>REM TKBT0 
>REM VMRT0 
>;
>; End of SYSGEN
>;
>TIME
00:35:52 13-AUG-04
>;
>ASN =
>;
>@ <EOF>
>
