>VCP CON SW:[KITS]PASV13UPD/TAP/RO/MOU:FOR/DRV:MU
VCP - Device VF0: (MU1:) has been assigned.
>BRU /NOI/UFD MU1: DU:
BRU - Starting Tape 1 on MU1:

BRU - End of Tape 1 on MU1:

BRU - Completed

>VCP DIS/USE
DMO -- TT62:   dismounted from MU1:    *** Final dismount initiated ***
>VCP CON SW:[KITS]PASV13/TAP/RO/DRV:MU/MOU:FOR
VCP - Device VF0: (MU1:) has been assigned.
>@[367,367]AUTOIN
RSX-11M/M-PLUS Auto-Install Procedure V1.1

          10-MAR-21    02:55:12


Type "?" for help; CTRL/Z to end; or valid input.

Which product(s) do you want to install? PAS

Type "?" for help; CTRL/Z to exit Auto-Install; or valid input.

Where are the update files located <DU0:>? 

Type "?" for help; CTRL/Z to skip this product; or valid input.

Which device are the distribution files for PAS (PAS) located on (include colon)? MU1:

BRU - Starting Tape 1 on MU1:

BRU - End of Tape 1 on MU1:

BRU - Completed

Products being installed:
    Device	Product	Task name
    ------	-------	---------
    MU1:   	PAS	(PAS)

Determining system configuration.

BRU - Starting Tape 1 on MU1:

BRU - End of Tape 1 on MU1:

BRU - Completed

WARNING -- no updates found for configuration data file; procedure continuing.

Do you want to customize PAS (PAS) (Y/N) <N>? Y

Which directory do you want the PASCAL task assigned to ([g,m]) <[1,1]>? [3,54]

Generate FPP or EIS code <FPP, EIS, UNKNOWN> <UNKNOWN>? FPP

Build the compiler using separate I & D space <NO>? Y

Allow future customization of this file <YES>? 

Print release notes automatically <NO>? 

Print the installation log automatically <NO>? 


Do you want to customize PAS (PAS) again (Y/N) <N>?  

Installation of PAS (PAS) beginning at 10-MAR-21 02:55:56

Reading PASPAS.CFG.

Transferring kit files to work area.

BRU - Starting Tape 1 on MU1:

BRU - End of Tape 1 on MU1:

BRU - Completed

BRU - Starting Tape 1 on MU1:

BRU - End of Tape 1 on MU1:

BRU - Completed

DMO -- TT62:   dismounted from MU1:    *** Final dismount initiated ***
Updating kit files.

Module "DATTIM" replaced

Module "DATTIM" replaced

Building product PAS (PAS).

Transferring files from work area.

Running IVP command procedure PASIVP.CMD.

PAS -- PDP-11 PASCAL V1.3-01
 
    23      I := J;  { Tests that message file is correctly installed - should  
give warning } 
                 ^150 
** PAS -- ERROR 150: W -- Must assign value before using variable               
                                         
 

PDP-11 PASCAL V1.3

As verification that the OTS is correctly installed,
you should now see a non-fatal run time warning

DOUBLE DEALLOCATION OF DYNAMIC MEMORY

** TT62 -- Warning -- Error   22
 
Double deallocation of dynamic memory
 
At PC =  002702
 
In  PASTST  At Or After   21
 
Installation of PAS (PAS) ending at 10-MAR-21 02:58:29.

Installation of PAS (PAS) successful.

Auto-Install ended on 10-MAR-21 at 02:58:30.

>
