RSX-11M/M-Plus Error Logging System V2.00 19-OCT-1988 14:00:39 Page 1 Entry Time Stamp Entry Type Device Error Type Additional Information ------- -------------------- ------------------ ------ ------------------------------ --------------------------------------- 92.1 19-OCT-1988 13:54:27 Device Soft Error DR001: Data Check Function = Read Data 92.2 19-OCT-1988 13:54:39 Device Soft Error DR001: Data Check Function = Read Data 92.3 19-OCT-1988 13:56:30 Device Soft Error DR001: ECC Hard Error Function = Read Data 93.1 19-OCT-1988 13:56:32 Device Soft Error DR001: Data Check Function = Read Data RSX-11M/M-Plus Error Logging System V2.00 19-OCT-1988 14:00:39 Page 2 Selection information: --------- ------------ Command line: =/DA:T Report file: DR1:[5,3]ERRREPORT.LST;1 Input file: DR0:[1,6]LOG.ERR;1 Report format selection: BRIEF WIDE Packet time selections: From 19-OCT-1988 00:00:00 through 19-OCT-1988 14:00:38 Volume label selection: (not used) Serial number selections: Drive: (not used) Pack: (not used) Summary selections: No History No Error No Geometry Packet type selections: Processor Memory System_Info Peripheral Control Packet number selections: *:* Device selections: (ALL) Number of packets printed / processed: 4. / 545. Processing began at 19-OCT-1988 14:00:25 Processing ended at 19-OCT-1988 14:02:03