COOLEY-TUKEY FAST FOURIER TRANSFORMS THIS TAPE CONTAINS THE FOLLOWING FILES: 1.) CTFFT.DOC THIS FILE 2.) CTFFT.F4 A 1-DIMENTIONAL FFT SUBROUTINE (FOURG) 3.) TESTF.F4 A TEST ROUTINE FOR FOURG 4.) TESTF.OUT THE OUTPUT PRODUCED BY TESTF 5.) CTFFTM.F4 A MULTI-DIMENTIONAL FFT SUBROUTINE(FOUR2) 6.) TESTFM.F4 A TEST ROUTINE FOR FOUR2 7.) TESTFM.OUT THE OUTPUT FROM TESTFM ALL PROGRAMS ARE REASONABLY WELL DOCUMENTED. THE LISTINGS SHOULD BE READ BY ANYONE DESIRING TO USE THE PROGRAMS. SOME POINTS OF INTEREST ARE: 1.) TEST PROGRAM OUTPUT IS WRITTEN TO DEVICE # 6 2.) ABOUT 58% OF THE TIME TO RUN TESTF WITH THE SUPPLIED DATA IS SPENT IN FOURG (NATURALLY) IN THE CODE FOLLOWING STATEMENT 180 (I.E. LINES FFG121-FFG125. 3.) THIS SAME PROGRAM AND DATA HAS BEEN RUN ON A CDC-6400 (FTN V3.0 OPT=1) UNDER SCOPE 3.2 WITH AN RMS RELATIVE ERROR = .6867E-07 WHICH CORRESPONDS TO DOUBLE PRECISION ON THE DECSYSTEM-10. 4.) THE FOUR2-TESTFM PROGRAM WAS RUN ON A 32-BIT HEX MACHINE WITH SOMEWHAT LESS PERFORMANCE: ARRAY RMS RELATIVE ERROR SIZE 32-BIT DECSYSTEM-10 8 X 2 .4771E-06 .4395E-08 8 X 32 .1051E-05 .1906E-07 8 X128 .3590E-05 .4255E-07 8 X512 .2543E-04 .2046E-06 5.) THESE PROGRAMS ARE NOT SUPPORTED HOWEVER PLEASE SEND ANY COMMENTS,SUGGESTIONS, COMPLAINTS ETC. TO: ASHLEY D. GRAYSON DECSYSTEM-10 SCIENTIFIC MARKETING DIGITAL EQUIPMENT CORPORATION 146 MAIN STREET MAYNARD, MASS. 01754