README.md
This UIC contains a few programs I developed for data acquisition.
These programs were developed for a PDP-11/t55 system that has
TE16 tape transports. The routines will allow you to input or
output data via a DR11-K digital interface or an AR11 analog
subsystem.
Included on this UIC are :
Fortran Programs :
ADORDA Input/output data via an AR11. User selectable
sample rate (up to at least 4000 Hz continious).
DR2TAP Input data from a DR11-K. User selectable sample
rate (up to at least 8000 Hz continious).
CLOCKS Can either turn the Line Frequency Clock off or
it can turn it on and set it to our systems
Digital Pathways TCU-150 time keeper.
TAPDSK Reads data put onto tape by ADORDA or DR2TAP and
outputs it to a disk file.
MACRO Subroutines :
LABWORK Miscillaneous AR11, DR11-K, TCU-150, and TE16
handling routines.
TAPEIO Connect to unmounted tapes to allow reading,
writting, and other various operations.
Command Files :
BLDLAB Compiles the source files on this UIC and builds
privlidged tasks that map to the I/O page via the
KCOM partition.
GO Runs ADORDA and DR2TAP
If you have a problem you can let me know. I don't promise to
fix it, but I may be able to help you out.
NOTICE A) These routines require that the K-LAB series must be built
on your system since the I/O page is mapped to KCOM.
NOTICE B) USE ALL SOFTWARE CONTAINED HERE AT YOUR OWN RISK !!!
The programs run fine on our system but if there are any
differences in the address assignments of your system
and what the program is set up for then the result could
be a SYSTEM CRASH. So please, check the DEFINE module in
LABWORK.MAC carefully before using!
NOTICE C) Please check the source files for additional comments
and documentation.
Richard A. Crawford
E-Systems Inc.
P.O. Box 1056 CBN-27
Greenville, Texas 75401
(214)457-6018 or outside Texas (800)527-1000